6
RX UNIT
ESPE Working
Mode
Indication
Suggested Action
NORMAL OP
SAFE
Muting Active
If unexpected OSSDs OFF with muting
active check Partial Muting Configuration.
NORMAL OP Override Active
SAFE
Override attention status
Trigger override button to force OSSDs
ON.
SAFE
Override timings failure
Check and repeat override activation
sequence. Check override connections.
Lamp Failure
TX UNIT
ESPE Working
Mode
Indication
Action
EMISSION
Emission
TEST
Test
If undesired Test check TEST line
connection.
FAILURE
LOCKOUT
Failure on micro-
processor(s)
Activate RESET line. If error persists
contact Datalogic Technical Support.
FAILURE
LOCKOUT
Failure on optics
Activate RESET line. If error persists
contact Datalogic Technical Support.
FAILURE
LOCKOUT
Comunication failure
Check the correct mounting of terminator
cap. Activate RESET line.
CRITICAL
FAILURE
LOCKOUT
Generic Non-resettable
failure
Turn ON/OFF ESPE. Shown Failure Code
corresponds to failures above with steady
leds.