4
BASIC CONFIGURATION MODE
The device can enter Basic Configuration during Normal Operation.
As soon as CONFIRM action after
configuration is executed the device automatically restarts in Normal Operation with the new
configuration.
Particular attention has to be taken during the basic configuration management and use.
Muting time-out “
” does not comply with the requirements of IEC 61496-1. Therefore all possible risks
must be considered and related precautions undertaken before selecting the “
”option.
A
Keep
CONFIRM
button pressed to enter Basic Configuration Mode.
A
Test Pattern
is shown on led interface,
carefully check that ALL led are lit
in sequence from 1 to 8, then
current configuration is shown.
B
Choose function to set by
SELECT
button, selected led blinks.
C
Configure selected function with
ENABLE
button (switch led on/off).
Repeat B-C steps until desired configuration is visualized.
E
Keep
CONFIRM
button pressed to authorize the new configuration
RX Function list
Function Led
#
Setting
(default in bold)
LED Status
Zone
Partial Muting
2 - 3
Zone A
Zone A+B
Zone A+B+C
Zone
A+B+C+D
Zone B
Zone C
EDM
4
Enabled
Disabled
Restart Mode
5
Auto
Manual
Muting direction
6
T (bidirectional)
L (monodirectional)
Muting Time-out
7
10 min
Inf.
Override sensor
8
Level
Edge