References
262
QuickScan™ I QD24XX/QBT24XX/QM24XX
RF Features
Automatic Configuration Update
When this feature is enabled, the base station and reader will keep their configurations syn-
chronized. If a reader's configuration is altered by reading programming labels, this change is
automatically transferred and updated in a linked base station. Likewise, if the base station's
configuration is changed using Aladdin or by host commands, then the reader's configuration
will automatically be updated if this feature is enabled.
RF Address Stamping
Source Radio Address Delimiter Character
This option specifies the delimiter character to be placed between the label data and radio
address when address stamping is enabled.
This feature only applies if
"Source Radio Address Transmission"
on page 221 is
enabled.
Follow these instructions to select the delimiter character:
1. Determine the desired character, then find its hexadecimal equivalent on the
on the inside back cover. A setting of 00 specifies no delimiter character.
2. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Pro-
gramming Mode.
3. Scan the bar code: SET SOURCE RADIO ADDRESS DELIMITER CHARACTER.
4. Scan the appropriate two digits from the keypad in
, that represent the
hexadecimal characters which were determined in the steps above. You will hear a two-
beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not
save the entry string. You can then start again at the beginning.
5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
Table 45. Source Radio Address Delimiter Character Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
No delimiter
character
, (comma)
- (dash)
/ (slash)
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SET SOURCE RADIO ADDRESS DELIMiTER CHARACTER
4
Scan Two Characters From
‘0’ and ‘0’
‘2’ and ‘C’
‘2’ and ‘D’
‘2’ AND ‘F’
5
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for QuickScan QM24 series
Page 18: ...Programming the Reader 8 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Page 188: ...Enter Exit Programming Mode Plessey 178 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Page 220: ...Symbology Selection 210 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Page 302: ...Keypad 292 QuickScan I QD24XX QBT24XX QM24XX A B C D E F...
Page 312: ...Scancode Tables 302 QuickScan I QD24XX QBT24XX QM24XX NOTES...