Enter/Exit Programming Mode
Code 11
154
QuickScan™ I QD24XX/QBT24XX/QM24XX
Code 11 Check Character Transmission
This feature enables/disables transmission of an optional Code 11 check character.
$CC1CT00(CR)
Code 11 Check Character Transmission = Don’t Send
$CC1CT01(CR)
Code 11 Check Character Transmission = Send
DEFAULT
Code 11 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Code 11
symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
$CC1LC00(CR)
Code 11 Length Control = Variable Length
$CC1LC01(CR)
Code 11 Length Control = Fixed Length
Summary of Contents for QuickScan QM24 series
Page 18: ...Programming the Reader 8 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Page 188: ...Enter Exit Programming Mode Plessey 178 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Page 220: ...Symbology Selection 210 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Page 302: ...Keypad 292 QuickScan I QD24XX QBT24XX QM24XX A B C D E F...
Page 312: ...Scancode Tables 302 QuickScan I QD24XX QBT24XX QM24XX NOTES...