6
QuickScan
®
L
Beeper Definitions
The scanner issues different beep sequences and patterns to indi-
cate status. The table below defines beep sequences that occur dur-
ing both normal scanning and while programming the scanner.
Beeper Sequence
Indication
Standard Use
L
ow/medium/high beep
Power up.
Short high beep
A barcode label was decoded (if decode
beeper is enabled).
4 long low beeps
A transmission error was detected in a
scanned barcode. The data is ignored.
This occurs if a unit is not properly con-
figured. Check option setting.
5 low beeps
Conversion or format error.
Low/high/low beep
ADF transmit error.
High/high/high/
low beep
RS-232 receive error.
Parameter Menu Scanning
Short high beep
Correct entry scanned or correct menu
sequence performed.
Low/high beep
Input error, incorrect barcode or
Cancel
scanned, wrong entry, incorrect barcode
programming sequence; remain in pro-
gram mode.
High/low beep
Keyboard parameter selected. Enter
value using barcode keypad.
High/low/high/
low beep
Successful program exit with change in
the parameter setting.
Low/high/low/
high beep
Out of host parameter storage space.
Scan
SET DEFAULTS on page 10
.
Code 39 Buffering
High/low beep
New Code 39 data was entered into the
buffer.
3 beeps - long high beep
Code 39 buffer is full.
Low/high/low beep
The Code 39 buffer was erased or there
was an attempt to clear or transmit an
empty buffer.