Input Wiring
4-3
Datalogic Automation, Inc.
This table describes the input characteristics.
Input Wiring
The diagram below shows how to wire a sensor to a general purpose or event input.
Note
: All connections to inputs must be made using properly grounded shielded cable.
All inputs are compatible with current sinking output signals. There is only one “Input Plus Common” connection for all
the inputs.
General Purpose Input Circuit
Input Resistance
(nominal)
Input
Voltage
Turn On
Current
Turn Off
Current
Maximum
Current
Isolated
Voltage
4.7k @
0-24 Vdc
>2 mA
< 0.16Ma
5.1 mA @ 24Vdc
1000 Vrms