STEP 6 - DEVICE CONFIGURATION
PRODUCT REFERENCE GUIDE
15
Advanced Setup for Software Adjustable Focus Models (Liquid
Lens)
To begin configuration, the reader must be correctly mounted at the correct reading dis-
tance for your application so that its Field of View covers the application reading area.
1. From the Task Area select Open Device Configuration.
2. The Open Device Configuration window opens showing the list of currently saved
configurations (jobs) saved on the device. For new devices, the only saved job is
the Default configuration. Click OK. The device enters run mode and begins acquir-
ing images.
3. Click on the Advanced Setup button and press the Play icon.
4. Place the
Grade A Barcode Test Chart
in the reading area. Once positioned, stop
image acquisition by clicking on the Pause button.