SOFTWARE CONFIGURATION
142
MATRIX 320
BM150 DISPLAY MODULE CONFIGURATION AND MESSAGES
The BM150 display module is an optional accessory for the CBX500 connection box.
Although independent, it is an extension of the reader's HMI Interface, so through its
keypad it provides execution of HMI features such as Test, Focus/Locate, Calibration and
Code Setting. It also displays device status information, reading results, diagnostic and
network messages. Since it connects through the BM100 backup memory module, it
provides access to Backup and Restore features through its Extended menu.
Configuration Through DL.CODE
BM150 must be detected through the BM100 backup memory module at power-up/
reset and this is done through a command setting in DL.CODE. By connecting the reader
to DL.CODE the following parameters can be managed.
In the Device>Settings>Settings>Maintenance window:
•
Enable BM100 Detection
Checked (Enabled): the BM100 backup memory module will be detected on
power-up/reset; therefore the BM150 display module (if present), will also be
enabled.
Unchecked (Disabled): the BM100 backup memory module will
not
be detected
on power-up/reset; therefore the BM150 display module (if present), will also
not
be enabled.
•
BM150 Display Layout (Master Only)
Reading Mask Only: the Reading Mask screen is sent to the BM150 display.
Reading Mask/Device State: the Reading Mask/Device State screen is sent to the
BM150 display.
Summary of Contents for Matrix 320
Page 1: ...Matrix 320 PRODUCT REFERENCE GUIDE Image Based Industrial Reader...
Page 88: ...CBX ELECTRICAL CONNECTIONS 74 MATRIX 320 Figure 54 NPN External Trigger Using Matrix 320 Power...
Page 133: ...Reader 2 Reader 3 PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 119...
Page 141: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 127...
Page 143: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 129 Open the cloned application job...