background image

MATRIX 300™ QUICK GUIDE 

 

 

SUPPORT THROUGH THE WEBSITE 

 
Datalogic  provides  several  services  as  well  as  technical  support  through  its  website.  Log  on  to 

www.datalogic.com

  and  click  on  the 

Industrial Automation

 links for further information: 

 

Products - Industrial Automation - Identification 

Select  your  product  from  the  links  on  the 

Identification

  page.  The  product  page  describes  specific  Info,  Features,  Applications, 

Models,  Accessories,  and  Downloads  including  documentation,  software  drivers,  and  the 

VisiSet™  utility  program,  which  allows 

device configuration using a PC through Serial and Ethernet interfaces. 

 

Support & Services - Industrial Automation 

Several  links  from  the 

Industrial  Automation

  list  take  you  to  additional  services  such  as:  Service  Program  which  contains 

Maintenance Agreements and Warranty Extensions; Repair Centers; On-Line RMA Return Material Authorizations; Technical Support 
through email or phone, Partner Program; Downloads for additional downloads. 

 
 

LEGAL NOTICES 

 
© 2013 Datalogic Automation S.r.l. 

 ALL RIGHTS RESERVED. 

 Protected to the fullest extent under U.S. and international laws. Copying, or 

altering of this document is prohibited without express written consent from Datalogic Automation S.r.l. 

Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. 

Matrix  300,  ID-NET,  VisiSet  and  X-PRESS  are  trademarks  of  Datalogic  Automation  S.r.l.  All  other  brand  and  product  names  mentioned 
herein are for identification purposes only and may be trademarks or registered trademarks of their respective owners. 

Datalogic  shall  not  be  liable  for  technical  or  editorial  errors  or  omissions  contained  herein,  nor  for  incidental  or  conseque ntial  damages 
resulting from the use of this material. 

Summary of Contents for Matrix 300

Page 1: ...Matrix 300 Reference Manual available on the mini DVD and also downloadable at www datalogic com 1 Device Class Label Bracket Mounting Holes 4 Good Read LED green Lens Cover Ethernet Connector No Rea...

Page 2: ...nts and Warranty Extensions Repair Centers On Line RMA Return Material Authorizations Technical Support through email or phone Partner Program Downloads for additional downloads LEGAL NOTICES 2013 Dat...

Page 3: ...One Shot or Phase Mode Operating mode is used the reader is activated by an External Trigger photoelectric sensor when the object enters its reading zone Figure 1 Matrix 300 in Stand Alone Layout CBX1...

Page 4: ...X Auxiliary Interface TX V Power Source Inputs RX Auxiliary Interface RX I2A Input 2 A polarity insensitive SGND Auxiliary Interface Reference I2B Input 2 B polarity insensitive ID NET V Power Referen...

Page 5: ...OSITION THE READER 1 To mount the Matrix 300 use the mounting bracket to obtain the most suitable position for the reader The most common mounting configuration is shown in the figure below Figure 2 P...

Page 6: ...ng Diagrams in the Appendix of this Quick Reference Guide to determine the distance your reader should be positioned at Further diagrams are provided in the Matrix 300 Reference Manual NOTE Rapid Conf...

Page 7: ...PRESS push button until the Aim LED is on Figure 4 X PRESS Interface Aim Autofocus Function 4 Release the button to enter the Aim function The laser pointers turn on and the Autofocus procedure begins...

Page 8: ...application specific code it can be ignored Figure 5 X PRESS Interface Aim Function Exit the Aim function by pressing the X PRESS push button once After a short delay the Aim function is cancelled an...

Page 9: ...button once After a short delay the Learn procedure is cancelled The Grade A Barcode Test Chart cannot be used to set the Code 128 symbology even though the reader successfully reads the code Use the...

Page 10: ...the configuration running Windows 98 2000 NT XP Vista 7 or 8 then insert the VisiSet Mini DVD wait for the DVD to autorun and follow the installation procedure This configuration procedure assumes a...

Page 11: ...11 STEP 6 CONFIGURATION USING SETUP WIZARD The Setup Wizard option is advised for rapid configuration or for new users It allows reader configuration in a few easy steps 1 Select the Setup Wizard but...

Page 12: ...cquires images and gives visual feedback in the view image window The Setup Wizard now shows four delimiters red points in the acquired images which indicate the region in which the calibration algori...

Page 13: ...flashes once acquiring the image and auto determines the best exposure and gain settings 5 Press the Fine Focusing button to activate the Focus procedure CAUTION For Liquid Lens models the Fine Focus...

Page 14: ...ndow reports the procedure progress in percentage At the end of the procedure the Reading Distance PPI and FOV data are reported 6 Now place a single application specific code in front of the reader a...

Page 15: ...tup Wizard window shows the code type results The Grade A Barcode Test Chart cannot be used to set the Code 128 symbology even though the reader successfully reads the code Use the application specifi...

Page 16: ...Saving Options choice and press the Save button 9 Close the Setup Wizard NOTE If your application has been configured using the VisiSet Setup Wizard your reader is ready If necessary you can use VisiS...

Page 17: ...he Test function Once entered the Bar Graph on the five LEDs is activated and if the reader starts reading codes the Bar Graph shows the Good Read Rate In case of no read condition only the STATUS LED...

Page 18: ...ATION USING VISISET Advanced configuration can be performed through the VisiSet program by selecting Device Get Configuration From Temporary Memory to open the Parameter Setup window in off line mode...

Page 19: ...ial interface See the Host Mode Programming file on the Mini DVD ALTERNATIVE LAYOUTS If you need to install an Ethernet network ID NET network or Fieldbus network refer to the Matrix 300 Reference Man...

Page 20: ...calibration Aim Autofocus to turn on the laser pointers to aid positioning Test with bar graph visualization to check static reading performance In normal operating mode the colors and meaning of the...

Page 21: ...See the Matrix 300 Reference Manual for a complete list of conditions For applications where DOF is important pre configured ini files are provided which correspond to these reading diagrams See the M...

Page 22: ...rix 300 Reference Manual for a complete list of conditions For applications where DOF is important pre configured ini files are provided which correspond to these reading diagrams See the Matrix 300 R...

Page 23: ...e the Matrix 300 Reference Manual for a complete list of conditions For applications where DOF is important pre configured ini files are provided which correspond to these reading diagrams See the Mat...

Page 24: ...Matrix 300 Reference Manual for a complete list of conditions For applications where DOF is important pre configured ini files are provided which correspond to these reading diagrams See the Matrix 3...

Page 25: ...rity insensitive see Reference Manual for details Outputs Output 1 2 and 3 NPN or PNP short circuit protected see Reference Manual for details OPTICAL FEATURES Image Sensor CMOS sensor with Global Shu...

Page 26: ...128 GS1 128 Code 39 Standard and Full ASCII Code 32 MSI Standard 2 of 5 Matrix 2 of 5 Interleaved 2 of 5 Codabar Code 93 Pharmacode EAN 8 13 UPC A E including Addon 2 and Addon 5 GS1 DataBar Family C...

Page 27: ...ix ECC 200 QR Code ISO IEC 15416 Code 128 Code 39 Interleaved 2 of 5 Codabar Code 93 EAN 8 13 UPC A E AS9132A Data Matrix ECC 200 AIM DPM Data Matrix ECC 200 QR Code USER INTERFACE LED Indicators Powe...

Page 28: ...3 73 54 2 13 M4 N 4 36 1 42 75 2 95 37 5 1 48 36 1 42 29 5 1 16 54 2 12 20 5 0 81 62 2 45 7 3 0 29 43 1 69 75 2 95 36 1 42 29 5 1 16 36 1 42 M4 n 4 37 5 1 48 OPTICAL AXES mm in OPTICAL AXES Matrix 300...

Page 29: ...IDE 29 Figure 13 Mounting Brackets Overall Dimensions 3 0 12 17 7 0 70 36 1 42 47 1 85 17 7 0 70 36 1 42 47 1 85 M 4 N 5 40 1 57 60 2 36 3 0 12 36 1 42 23 0 91 4 5 0 18 8 2 0 32 9 0 47 1 85 90 4 5 0 1...

Page 30: ...eference Manual for the Declaration of Conformity For installation use and maintenance it is not necessary to open the reader Only connect Ethernet and dataport connections to a network which has rout...

Page 31: ...Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures LASER SAFETY The Matrix 300 internal illuminators c...

Page 32: ...quipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmfu...