7.4.3 Synchronized ID-NET Network Configurations
The Synchronized ID-NET network communications between Master and Slave are internally
managed by the application software. A pre-configured job is loaded with the Synchronized
Layout Type and the correct Operating Mode for both the Master and Slaves when either the
Phase Mode or PackTrack Configuration is selected from the Internal Network Setting
feature.
1. Complete the configuration of all the application parameters (including Image Setup) and
save them to the Master with an application relative name and
with
the option to
Clone
Master configuration on Slaves
.
Figure 84
– Saving Synchronized Phase Mode Configuration to Master
2. Connect to each Slave reader via Ethernet (see note below), and set the Slave specific
parameters.
NOTE:
If necessary, Slave device photometric (Image Setup) parameters
must be configured separately through DL.CODE. This is preferably done
through each device’s Ethernet TCP/IP channel. If Slave devices are not
connected to Ethernet you must temporarily (manually) connect them one by
one to perform Image Setup.