When the job opens, pause run mode and configure the Slave specific parameters. These
depend on the application and include the following:
photometric parameters (Image Auto-Setup feature in the Image Setup step)
Acquisition Trigger Delays necessary to avoid lighting interference between adjacent
or oppositely positioned readers (Reading Phase step)
Images Saving if used (Data Formatting step)
Encoder Sensor: if used, (for all Slaves, the Encoder Type must be set to
Internal
)
Verify the focus and decoding with the capture image
and Code Setup page.