Installation Overview
Product Reference Guide
2-25
Scale Diagnostic Mode
To enter Scale Diagnostic Mode, press the Scale Zero Push Button for
approximately four seconds. Six rapid tones will be sounded, indicating
the unit is leaving normal operation and entering Scale Diagnostic Mode.
The Remote Display will flash a ‘1’ across the display while the dignostic
routine is being run. When diagnostics are completed successfully, the dis-
play will indicate that the unit has passed the diagnostic test by displaying
. Next, the display shows a listing of how many times the unit
has been calibrated and zeroed in the form of:
where x equals
the number of times the scale has been calibrated. Next, the unit will dis-
play
where x is the number of times the scale has been zeroed.
Finally, all segments will be displayed in the form of:
to allow
visual verification of display function.
If the diagnostics routine is not completed successfully, the scanner will
sound a series of tones and the Remote Display will show an error code.
Turn to
Chapter 4
,
Problem Isolation
for a description of error codes.
Press the Scale Zero Push Button once more to reset the unit and exit
Scale Diagnostic Mode. See the topic,
Scanner and Scale Reset
in Chapter
3 for more information about unit resets.
Cables & Connections
Considerations when routing the power and interface cables for the scan-
ner and scanner/scale are:
•
Ensure that cables are not pinched, kinked or pierced.
•
Do not route interface cables in close proximity to electrical motors
or other sources of electromagnetic interference.
•
Cables can drop directly from their connectors on the scanner, or,
alternatively, can be routed along the scanner’s side to the back (see
Figure 2-11
).
Do not plug the AC power cord into the outlet at this time. It is a good
practice to always connect the power cable to the scanner first before plug-
ging it into the AC receptacle. The procedures titled, Set-Up, provided
later in this chapter will instruct you to connect the power cord at that
time.
Figure 2-11
illustrates the basic cable routing scheme.
PASS
c
XXX
Zero
XXXX
c
XXX
-18.8.88
Summary of Contents for Magellan 9500?
Page 1: ...Magellan 9500 9500 9504 9504 with SmartSentry Product Reference Guide...
Page 28: ...1 16 Magellan 9500 NOTES...
Page 100: ...4 14 Magellan 9500 NOTES...
Page 116: ...5 16 Magellan 9500 NOTES...
Page 396: ...6 280 Magellan 9500 NOTES...
Page 416: ...B 10 Magellan 9500 NOTES...
Page 426: ...D 2 Magellan 9500 NOTES...
Page 442: ...E 16 Magellan 9500 NOTES...
Page 458: ...F 16 Magellan 9500 NOTES...