Error Codes
Product Reference Guide
1-5
Error Codes
Upon startup, if the scanner flashes its indicator LED or sounds an unexpected series of beep
tones (other than normal power-up indications), this means the scanner has not passed its auto-
matic Selftest and has entered FRU
1
isolation mode. If the scanner is reset or the button is
pressed, the sequence will be repeated. The following table describes the LED flashes/beep codes
associated with an error found.
1. Field Replaceable Unit (FRU)
NUMBER OF
LED FLASHES/
BEEPS
ERROR
CORRECTIVE ACTION
1
Configuration
Contact Helpdesk for assistance
2
Interface PCB
6
Main PCB
10
Button Error
11
Near Field
Imager Module
12
Far Field
Imager Module
13
Software ID
Failure
14
CPLD/Code
Mismatch