background image

GS1 DataBar Limited

Product Reference Guide

                           5-25

GS1 DataBar Limited — continued

GS1 DataBar Limited 128 Emulation

When enabled, GS1 DataBar Limited barcodes will be translated to the GS1 128 label data for-
mat.

Minimum Reads

This feature specifies the minimum number of consecutive times an GS1 DataBar Limited label 
must be decoded before it is accepted as a good read.

START / END

PROGRAMMING BAR CODES

Disable GS1 DataBar Limited 128 Emulation

DEFAULT

Enable GS1 DataBar Limited 128 Emulation

START / END

PROGRAMMING BAR CODES

Minimum = 1 Read

DEFAULT

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

Summary of Contents for MAGELLAN 1400I

Page 1: ...Magellan 1400i Omni Directional Imaging Scanner Product Reference Guide...

Page 2: ...5144118 5146463 5179270 5198649 5200597 5202784 5208449 5210397 5212371 5212372 5214270 5229590 5231293 5232185 5233169 5235168 5237161 5237162 5239165 5247161 5256864 5258604 5258699 5260554 5274219...

Page 3: ...10 Aiming Pointer 2 10 Targeted Scanning Mode 2 10 Wake Up Intensity 2 13 Interface Selection 3 3 Interface Features 3 7 RS 232 Interface Features 3 9 ACK NAK Error Handling 3 23 USB OEM Interface Fe...

Page 4: ...GS1 DataBar Limited 5 24 GS1 DataBar Limited 128 Emulation 5 25 Minimum Reads 5 25 Code 39 5 26 Disable Enable Code 39 5 26 Check Character Calculation 5 26 Check Character Transmit 5 27 Start Stop Ch...

Page 5: ...th 2 Programming Instructions 5 59 MSI Plessey Stitching 5 60 Minimum Reads 5 61 Standard 2 of 5 5 62 Disable Enable Standard 2 of 5 5 62 Check Digit Verification 5 62 Check Digit Transmit 5 63 Length...

Page 6: ...iv Magellan 1400i NOTES...

Page 7: ...Guide QRG Copies of other publications for this product are downloadable free of charge from the website listed on the back cover of this manual On leaving the factory units are programmed for the mos...

Page 8: ...supply AC Adapter Plug the AC Adapter barrel connector into the socket on the RS 232 cable con nector and the AC Adapter plug into a standard power outlet Figure 1 RS 232 Serial or USB Connection usi...

Page 9: ...your scanner Some programming barcode labels like the label below for resetting defaults require only the scan of that single label to enact the change Most of the programming labels in this manual h...

Page 10: ...Host Disable Constant green flash at 1 Hz 100mS on 900mS off The scanner is disabled due to receiving a disble command from the POS terminal Diagnostics Varies see Error Codes on page 1 5 for more in...

Page 11: ...ered FRU1 isolation mode If the scanner is reset or the button is pressed the sequence will be repeated The following table describes the LED flashes beep codes associated with an error found 1 Field...

Page 12: ...Getting Started 1 6 Magellan 1400i NOTES...

Page 13: ...out The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again e g two identical items in succession START END PROGRAMMING BAR CODES...

Page 14: ...gone timeout duration using hex values from 000 to 255 in increments of ten milliseconds 10ms or 0 01 seconds To configure this feature scan the START END bar code above to place the unit in Programm...

Page 15: ...ide 2 3 Sleep Mode This feature specifies the amount of time with no bar code reads before the scanner enters sleep mode START END PROGRAMMING BAR CODES 15 Seconds DEFAULT 30 Seconds 1 Minute 2 Minute...

Page 16: ...General Features 2 4 Magellan 1400i Sleep Mode cont START END PROGRAMMING BAR CODES 6 Minutes 7 Minutes 8 Minutes 9 Minutes 10 Minutes DEFAULT 12 Minutes 15 Minutes 30 Minutes 1 Hour...

Page 17: ...ce Guide 2 5 LED and Beeper Indicators Power On Alert Disables or enables the indication a single beep that the scanner has finished all its power up tests and is now ready for operation START END PRO...

Page 18: ...lly reading a bar code Choices are Good Read Indicate after decode Good Read Indicate after transmit Good Read Indicate after CTS goes inactive then active NOTE This option Indicate after CTS goes ina...

Page 19: ...ep upon a successful decode of a bar code Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low medium or high frequency selectable from the list below Controls the beeper s...

Page 20: ...eneral Features 2 8 Magellan 1400i Good Read Beep Length Specifies the duration of a good read beep START END PROGRAMMING BAR CODES 60msec DEFAULT 80msec 100msec 120msec 140msec 160msec 180msec 200mse...

Page 21: ...appended to decoded data before being presented to the POS The PIR feature allows the scanner to provide information to an external computer indicating how easy the label was to read START END PROGRA...

Page 22: ...rget Mode Active Time Target Mode Linger Time START END PROGRAMMING BAR CODES Disable DEFAULT Enable always on NOTE When add ons are enabled and a bar code is being read while in Targeted Mode positio...

Page 23: ...2 11 Target Mode Active Time Specifies the time duration the scanner attempts to decode labels while in the targeted mode of operation START END PROGRAMMING BAR CODES Extra Short Duration Short Durat...

Page 24: ...Mode The linger timer starts upon a good read or upon timeout of Target Mode Active Time whichever is earliest A button press at any time will reset the process back to the start NOTE Active Time and...

Page 25: ...Up Intensity This feature indicates the percentage of ambient light change which will trigger the scanner to wake up from Sleep Mode Lower settings provide greater sensitivity START END PROGRAMMING B...

Page 26: ...General Features 2 14 Magellan 1400i Wake Up Intensity cont START END PROGRAMMING BAR CODES 40 50 60 70 80...

Page 27: ...683 Port 9B 3 24 Keyboard Wedge La 3 30 IBM 4683 Port 17 3 24 Keyboard Wedge Ma 3 30 USB Keyboard Wedge Na 3 30 USB OEM 3 24 Keyboard Wedge Na 3 30 USB Keyboard 3 24 Keyboard Wedge Oa 3 30 Wand Emulat...

Page 28: ...85 325 Style IBM Enhanced PC M WYSE 60 85 99 GT 150 160 285 ANSI Keyboard 105 Keys 520 520 ES ANSI Keyboard 105 Keys WYSE 55 65 65 ES 120 185 325 ANSI Keyboard 105 Keys N WYSE 60 85 99 GT 150 160 285...

Page 29: ...t Reference Guide 3 3 Interface Selection START END PROGRAMMING BAR CODES RS 232 Standard RS 232 Wincor Nixdorf IBM 4683 Port 5B IBM 4683 Port 9B IBM 4683 Port 17 USB OEM USB Keyboard USB RS 232 Wand...

Page 30: ...4 Magellan 1400i Interface Selection cont START END PROGRAMMING BAR CODES Keyboard Wedge B Keyboard Wedge C Keyboard Wedge D Keyboard Wedge E Keyboard Wedge F Keyboard Wedge G Keyboard Wedge H Keyboa...

Page 31: ...eference Guide 3 5 Interface Selection cont START END PROGRAMMING BAR CODES Keyboard Wedge K Keyboard Wedge L Keyboard Wedge M Keyboard Wedge N Keyboard Wedge O Keyboard Wedge P Keyboard Wedge Q Keybo...

Page 32: ...terface Related Features 3 6 Magellan 1400i Interface Selection cont START END PROGRAMMING BAR CODES Keyboard Wedge T Keyboard Wedge U Keyboard Wedge V Keyboard Wedge W Keyboard Wedge X Keyboard Wedge...

Page 33: ...et to ignore host commands the scanner will ignore all host commands except for the minimum set necessary to keep the interface active and transmit labels For normal operation of the interface select...

Page 34: ...is being transmitted to the host Selecting BUFFERS 1 means that the first barcode must be transmitted before a new one can be read A selection of BUFFERS 2 means that a new barcode can be read while...

Page 35: ...Interface Features Product Reference Guide 3 9 RS 232 Interface Features START END PROGRAMMING BAR CODES 1200 Baud 2400 Baud 4800 Baud 9600 Baud DEFAULT 19200 Baud 38400 Baud 57600 Baud 115200 Baud...

Page 36: ...e Related Features 3 10 Magellan 1400i RS 232 Interface Features cont START END PROGRAMMING BAR CODES 7 Data Bits 8 Data Bits DEFAULT 1 Stop Bit DEFAULT 2 Stop Bits Parity None DEFAULT Parity Even Par...

Page 37: ...smission of data to the host Enable CTS Scan Control The CTS line must be active for the scanner to read and trans mit data While the CTS line is inactive the scanner remains in a host disabled state...

Page 38: ...sion speed is too high the system may not be able to receive all characters You may need to adjust the delay to make the system work properly START END PROGRAMMING BAR CODES Inter Char Delay No Delay...

Page 39: ...y cont Software Flow Control Disables Enables software control using XON XOFF characters START END PROGRAMMING BAR CODES Interchar Delay 80 msec Interchar Delay 90 msec START END PROGRAMMING BAR CODES...

Page 40: ...ample one of the devices in the chain is a terminal where someone is entering data while another person is simultaneously scanning a barcode requiring transmission to the host the scanner will wait fo...

Page 41: ...he scanner will break the host echo loop to transmit the barcode data that has just been scanned to the host START END PROGRAMMING BAR CODES Host Echo Quiet Interval 0msec Host Echo Quiet Interval 10m...

Page 42: ...ecifies whether the RS 232 interface provides TTL levels on the output pins TxD and RTS START END PROGRAMMING BAR CODES Host Echo Quiet Interval 80msec Host Echo Quiet Interval 90msec Host Echo Quiet...

Page 43: ...f RS 232 TXD and RXD signals Beep on ASCII BEL Enables disables ability of scanner to beep sound a good read tone on receiving an ASCII BEL 07 hex START END PROGRAMMING BAR CODES Disable RS 232 Invert...

Page 44: ...RS 232 Interface Features cont Beep on Not on File Select for the host to beep or not when a not on file host command condition is detected by the host START END PROGRAMMING BAR CODES Disable Beep on...

Page 45: ...in error Selections for this option are Disable Enable for label transmission the scanner expects an ACK NAK response from the host when a label is sent Enable for host command acknowledge the scanne...

Page 46: ...ting your desired character Exit programming mode by again scanning the START END barcode above DEFAULT SETTING FOR THIS FEATURE 006 ACK Set ACK Character START END PROGRAMMING BAR CODES Sets the NAK...

Page 47: ...em specifies the time the scanner will wait for an ACK character from the host following a label transmission 000 Infinite timeout 001 075 Timeout in 200 millisecond increments To configure this featu...

Page 48: ...Retry for the specified number of times 255 Retry forever To configure this feature scan the START END barcode above to place the unit in Programming Mode then the Set ACK NAK Retry Count followed by...

Page 49: ...ost Errors include unrecognized host commands and com munication errors such as parity or framing errors Choices are 00 Ignore errors detected recommended setting 01 Process error as valid ACK charact...

Page 50: ...ntified as one of two different types of barcode scanners Depending on what other scanners you may already have connected to a USB OEM POS you may need to change this setting to enable all devices to...

Page 51: ...t a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host This applies to Code 128 Codabar and Code 93 for USB OEM Code 128 Codabar and Code 93 for I...

Page 52: ...nd Emulation Bar Code Format The following format settings are required for the wand emulation interface These settings have been pre configured at the factory for Wand Emulation scanners UPC A barcod...

Page 53: ...ll be transmitted as a high voltage level 2 4 to 5 25V and space as low level 0 to 0 7V Wand Idle State This feature specifies the level of the wand output signal when idle TTL logic levels High volta...

Page 54: ...the width of the minimum narrow bar 330 microseconds 660 microseconds Transmit Trailing Noise The transmission of noise pulses after the label may be enabled or disabled START END PROGRAMMING BAR COD...

Page 55: ...e enabled or disabled Symbology Conversion Wand Emulation can convert all barcodes to a single symbology Choices are No Conversion Convert to Code 39 Convert to Code 128 START END PROGRAMMING BAR CODE...

Page 56: ...e process that doesn t require any changes of software or hard ware Keyboard Layout The Keyboard Layout option supports many countries For details about Keyboard Layout please refer to your operating...

Page 57: ...Interface Features Product Reference Guide 3 31 Keyboard Wedge cont START END PROGRAMMING BAR CODES Italy Norway Portugal Spain Sweden Switzerland Japan 106 Key Hungary Czech...

Page 58: ...Keyboard Wedge cont Caps Lock State Specifies the format in which the scanner sends character data START END PROGRAMMING BAR CODES Slovakia Romania Croatia Poland START END PROGRAMMING BAR CODES Disab...

Page 59: ...commended that you enable this function if you are working without a keyboard installation It simulates keyboard timing and passes the keyboard status to the PC during power on NOTE This feature does...

Page 60: ...ontrol characters to host Send characters between 00H and 1FH according to a special function key mapping table This is used to send keys that are not in the normal ASCII set a unique set is pro vided...

Page 61: ...START END PROGRAMMING BAR CODES Selectable from 000 no interval to 255 in 10 msec increments To configure this feature scan the START END barcode above to place the unit in Programming Mode then the...

Page 62: ...receive all characters You may need to adjust the delay to make the system work properly Selectable from 000 to 255 in 10msec increments To configure this feature scan the START END barcode above to p...

Page 63: ...ing is not a mandatory requirement Data editing is sophisticated feature allowing highly customizable output for advanced users Factory default settings for data editing is typically set to NONE A pre...

Page 64: ...llar sign as a prefix 2 Scan the START barcode 3 Scan the SET PREFIX barcode 4 Reference the ASCII Chart on the inside back cover of this manual to find the hex value assigned to the desired character...

Page 65: ...e the unit in Programming Mode then the Set Prefix or Set Suffix followed by the digits from the Alphanumeric table in Appendix C Alpha Numeric Pad representing your desired character s Reference the...

Page 66: ...followed by A code character see the table below followed by A modifier character the modifier character is symbol dependent Figure 4 3 AIM ID SYMBOLOGY CHAR SYMBOLOGY CHAR UPC EAN E Code 128 EAN 128...

Page 67: ...r BEFORE or AFTER by scanning the appropriate bar code 3 Scan a barcode to select the symbology for which you wish to configure a custom Label ID 4 Determine the desired character s you may choose eit...

Page 68: ...UPC A Label ID Character s DEFAULT SETTING FOR THIS FEATURE A 41 hex DEFAULT SETTING FOR THIS FEATURE A 41 hex Set UPC A w P2 Addon Label ID Character s Set UPC A w P5 Addon Label ID Character s DEFAU...

Page 69: ...TURE E 45 hex Set UPC E w C128 Addon Label ID Character s Set EAN 8 Label ID Character s DEFAULT SETTING FOR THIS FEATURE FF 4646 hex DEFAULT SETTING FOR THIS FEATURE FF 4646 hex Set EAN 8 w P2 Addon...

Page 70: ...S FEATURE F 46 hex Set EAN 13 w C128 Addon Label ID Character s Set ISBN Label ID Character s DEFAULT SETTING FOR THIS FEATURE I 49 hex DEFAULT SETTING FOR THIS FEATURE IA 4941 hex Set IATA Label ID C...

Page 71: ...ING FOR THIS FEATURE RX 5258 hex Set GS1 DataBar Expanded Label ID Character s Set GS1 DataBar Limited Label ID Character s DEFAULT SETTING FOR THIS FEATURE RL 524C hex DEFAULT SETTING FOR THIS FEATUR...

Page 72: ...EATURE 40 hex DEFAULT SETTING FOR THIS FEATURE s 73 hex Set Std 2 of 5 Label ID Character s Set PDF417 Label ID Character s DEFAULT SETTING FOR THIS FEATURE P 5000 hex DEFAULT SETTING FOR THIS FEATURE...

Page 73: ...ode data to either all lower case a through z or all upper case A through Z characters NOTE Case conversion affects ONLY scanned barcode data and does not affect Label ID Prefix Suffix or other append...

Page 74: ...on BG25TB82 The A characters were converted to the B character and the 1 characters were converted to the numeral 2 character Nothing is done with the last two character pairs since they are all FF To...

Page 75: ...ence Appendix D Default Settings for default exceptions for your interface UPC A Disable Enable UPC A When disabled the scanner will not read UPC A barcodes UPC A Pharmacode 39 UPC E Transmit Function...

Page 76: ...A barcode data Expand UPC A to EAN 13 Expands UPC A data to the EAN 13 data format Selecting this feature also changes the sym bology ID to match those required for EAN 13 START END PROGRAMMING BAR C...

Page 77: ...imum Reads This feature specifies the minimum number of consecutive times a UPC A label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Disable Number System Trans...

Page 78: ...e Minimum Reads This feature specifies the minimum number of consecutive times an in store printed label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum 1...

Page 79: ...C E When disabled the scanner will not read UPC E barcodes Check Digit Transmission Enable this option to transmit the check digit along with UPC E barcode data START END PROGRAMMING BAR CODES Disable...

Page 80: ...ot with scanned barcode data Expand UPC E to UPC A Enables disables expansion of UPC E labels to UPC A Selecting this feature also changes the symbology ID to match those required for UPC A START END...

Page 81: ...D to match those required for EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times a UPC E label must be decoded before it is accepted as a good read START END PROGRAMMI...

Page 82: ...ing options apply to the GTIN label data format Expand UPC EAN to GTIN When this feature is enabled the scanner will translate UPC EAN labels to the 14 digit GTIN format START END PROGRAMMING BAR CODE...

Page 83: ...13 When disabled the scanner will not read EAN 13 barcodes Check Digit Transmission Enable this option to transmit the check digit along with EAN 13 barcode data START END PROGRAMMING BAR CODES Disab...

Page 84: ...at contain ISBN International Standard Book Number and appends an ISBN check character to the end of the label These codes are used for books and magazines Labels with ISBN codes start with 978 Exampl...

Page 85: ...d Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum 1 Read DEFAU...

Page 86: ...8 When disabled the scanner will not read EAN 8 barcodes Check Digit Transmission Enable this option to transmit the check Digit along with EAN 8 barcode data START END PROGRAMMING BAR CODES Disable...

Page 87: ...y ID to match those required for EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 8 label must be decoded before it is accepted as a good read START END PROGR...

Page 88: ...AN Two Label Combined Enables disables the transmitting of an EAN two label pair as one label START END PROGRAMMING BAR CODES Disable EAN Two Label Enable EAN Two Label START END PROGRAMMING BAR CODES...

Page 89: ...ed options are None This option directs the scanner to ignore add on portion of a UPC EAN barcode but still read the main portion of the barcode 2 Digits The scanner will optionally read 2 digit add o...

Page 90: ...TART END PROGRAMMING BAR CODES Disable Optional 2 Digit Add ons DEFAULT Enable Optional 2 Digit Add ons Disable Optional 5 Digit Add ons DEFAULT Enable Optional 5 Digit Add ons Disable Optional Code 1...

Page 91: ...r Omnidirectional When this feature is disabled the scanner will not read GS1 DataBar Omnidirectional barcodes GS1 128 Emulation When enabled GS1 DataBar Omnidirectional barcodes will be translated to...

Page 92: ...al continued Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Omnidirec tional label must be decoded before it is accepted as a good read START END PROGRAMMIN...

Page 93: ...abled the scanner will not read GS1 DataBar Expanded barcodes GS1 DataBar Expanded 128 Emulation When enabled GS1 DataBar Expanded barcodes will be translated to the GS1 DataBar Expanded 128 label dat...

Page 94: ...ength 1 to the first fixed length by following the GS1 DataBar Expanded Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed...

Page 95: ...Set Length 1 or Set Length 2 barcode 3 Turn to Appendix C Alpha Numeric Pad and scan the three digits zero padded represent ing the length in decimal notation 4 Scan the START END barcode NOTE For GS...

Page 96: ...ontinued Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Expanded label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES...

Page 97: ...anded Expanded Stacked continued Coupon Read Control This feature controls coupon reading START END PROGRAMMING BARCODES Disable coupon filtering Enable UPCA coupon decoding Disable GS1 DataBar coupon...

Page 98: ...options apply to the GS1 DataBar Limited symbology Disable Enable GS1 DataBar Limited When this feature is disabled the scanner will not read GS1 DataBar Limited barcodes START END PROGRAMMING BAR COD...

Page 99: ...ata for mat Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Limited label must be decoded before it is accepted as a good read START END PROGRAMMING BAR COD...

Page 100: ...ead Code 39 barcodes Check Character Calculation When enabled the scanner will calculate the check character of the labels Turn this option on only when a checksum is present in the Code 39 labels STA...

Page 101: ...er with scanned barcode data Start Stop Characters Enables disables transmission of Code39 start and stop characters START END PROGRAMMING BAR CODES Disable Check Char Transmission Enable Check Char T...

Page 102: ...1400i Code 39 continued Code 39 Full ASCII Enables disables the translation of Code 39 characters to Code 39 full ASCII characters START END PROGRAMMING BAR CODES Disable Code 39 Full ASCII DEFAULT E...

Page 103: ...code 4 Set Length 1 to the first fixed length by following the Code 39 Length 1 Length 2 Program ming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed...

Page 104: ...ND barcode Quiet Zones This feature enables disables the requirement that quiet zones must be present for Code 39 bar codes NOTE For Code 39 barcodes all check data and full ASCII shift characters eve...

Page 105: ...by the scanner s soft ware and the data will be decoded if all barcode proofing requirements are met Minimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must...

Page 106: ...re is disabled the scanner will not read Pharmacode 39 barcodes Start Stop Characters Enables or disables transmission of Pharmacode 39 start stop characters START END PROGRAMMING BAR CODES Disable Ph...

Page 107: ...e 5 33 Pharmacode 39 continued Check Character Transmit Enable this option to transmit the check character with scanned barcode data START END PROGRAMMING BAR CODES Disable Check Char Transmission Ena...

Page 108: ...hen this feature is disabled the scanner will not read Code 128 barcodes UCC EAN 128 Enables disables ability of scanner to translate UCC EAN 128 labels to the EAN 128 data format START END PROGRAMMIN...

Page 109: ...nsmit Function Characters Enables disables transmission of Code128 function characters 1 2 3 and 4 Function codes are transmitted as follows FNC1 80 hex FNC2 81 hex FNC3 82 hex FNC4 83 hex START END P...

Page 110: ...barcode 4 Set Length 1 to the first fixed length by following the Code 128 Length 1 Length 2 Pro gramming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one f...

Page 111: ...n the three digits zero padded represent ing the length in decimal notation 4 Scan the END barcode Code 128 Conversion to Code 39 Enables disables expansion of Code 128 labels to Code 39 NOTE For Code...

Page 112: ...embled by the scanner s software and the data will be decoded if all barcode proofing requirements are met Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label...

Page 113: ...When this feature is disabled the scanner will not read Interleaved 2 of 5 barcodes Check Digit Calculation When enabled the scanner will calculate the check digit of the labels START END PROGRAMMING...

Page 114: ...0i Interleaved 2 of 5 continued Check Digit Transmit Enable this option to transmit the check digit with scanned barcode data START END PROGRAMMING BAR CODES Disable Check Digit Calculation DEFAULT En...

Page 115: ...Length 1 to the first fixed length by following the Interleaved 2 of 5 Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed...

Page 116: ...endix C Alpha Numeric Pad and scan the three digits zero padded represent ing the length in decimal notation 4 Scan the END barcode NOTE For Interleaved 2 of 5 barcodes lengths must be an even number...

Page 117: ...leaved 2 of 5 bar code are presented to the scanner with this feature enabled the barcode parts will be assembled by the scanner s software and the data will be decoded if all barcode proofing require...

Page 118: ...Minimum Reads This feature specifies the minimum number of consecutive times an Interleaved 2 of 5 label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum 1...

Page 119: ...ture is disabled the scanner will not read Codabar barcodes Check Character Verification When enabled the scanner will verify the check character of the labels START END PROGRAMMING BAR CODES Disable...

Page 120: ...400i Codabar continued Check Character Transmit Enable this option to transmit the check character with scanned barcode data START END PROGRAMMING BAR CODES Disable Check Char Transmission Enable Chec...

Page 121: ...code 4 Set Length 1 to the first fixed length by following the Codabar Length 1 Length 2 Program ming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed...

Page 122: ...in decimal notation 4 Scan the END barcode Quiet Zones This feature enable disables the requirement that quiet zones must be present for Codabar bar codes NOTE For Codabar barcodes all start stop che...

Page 123: ...n Start Stop Character Transmission The transmission of start and end characters of Codabar is selected below START END PROGRAMMING BAR CODES Start Stop Type ABCD TN E Start Stop Type ABCD ABCD Start...

Page 124: ...label are presented to the scanner with this feature enabled the barcode parts will be assembled by the scanner s soft ware and the data will be decoded if all barcode proofing requirements are met S...

Page 125: ...ed Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum 1 Read DEFA...

Page 126: ...i Code 93 The following options apply to the Code 93 symbology Disable Enable Code 93 When this feature is disabled the scanner will not read Code 93 barcodes START END PROGRAMMING BAR CODES Disable C...

Page 127: ...code 4 Set Length 1 to the first fixed length by following the Code 93 Length 1 Length 2 Program ming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed...

Page 128: ...arcode 3 Turn to Appendix C Alpha Numeric Pad and scan the three digits zero padded represent ing the length in decimal notation 4 Scan the END barcode NOTE For Code 93 barcodes only the data characte...

Page 129: ...by the scanner s soft ware and the data will be decoded if all barcode proofing requirements are met Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must...

Page 130: ...sabled the scanner will not read MSI Plessey barcodes Check Digit Verification This feature specifies whether one or two check digits are to be calculated and verified START END PROGRAMMING BAR CODES...

Page 131: ...t check digits depending upon the setting for check digit verification Number of Check Characters Specifies number of MSI Plessey check characters to be calculated and verified START END PROGRAMMING B...

Page 132: ...et Length 1 to the first fixed length by following the MSI Plessey Length 1 Length 2 Pro gramming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed leng...

Page 133: ...2 barcode 3 Turn to Appendix C Alpha Numeric Pad and scan the three digits zero padded represent ing the length in decimal notation 4 Scan the END barcode NOTE For MSI Plessey barcodes all check and d...

Page 134: ...y label are presented to the scanner with this feature enabled the barcode parts will be assembled by the scanner s software and the data will be decoded if all barcode proofing requirements are met N...

Page 135: ...nued Minimum Reads This feature specifies the minimum number of consecutive times an MSI Plessey label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum 1 Re...

Page 136: ...is feature is disabled the scanner will not read Standard 2 of 5 barcodes Check Digit Verification When enabled the scanner will verify the check digit of the labels START END PROGRAMMING BAR CODES Di...

Page 137: ...Guide 5 63 Standard 2 of 5 continued Check Digit Transmit When this option is enabled the scanner will transmit the check digit START END PROGRAMMING BAR CODES Disable Check Digit Transmission Enable...

Page 138: ...ngth 1 to the first fixed length by following the Standard 2 of 5 Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 000 if there is only one fixed length...

Page 139: ...gth 2 barcode 3 Turn to Appendix C Alpha Numeric Pad and scan the three digits zero padded represent ing the length in decimal notation 4 Scan the END barcode NOTE For Standard 2 of 5 barcodes all che...

Page 140: ...rd 2 of 5 label are presented to the scanner with this feature enabled the barcode parts will be assembled by the scanner s software and the data will be decoded if all barcode proofing requirements a...

Page 141: ...tinued Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as a good read START END PROGRAMMING BAR CODES Minimum...

Page 142: ...Symbologies 5 68 Magellan 1400i...

Page 143: ...Product Reference Guide 6 1 2D Symbologies Advanced Decoding Features NOTE The features in this section are available ONLY for models with 2D features activated...

Page 144: ...arcode types PDF 417 and Datamatrix Options for each symbology are included in this addendum Factory Defaults for the std RS 232 interface are indicated in bold text throughout PDF 417 Disable Enable...

Page 145: ...3 Scan the END barcode 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 00 if there is only o...

Page 146: ...or Set Length 2 barcode 3 Turn to Alpha Numeric Pad and scan the four hex digits representing the length in hexidec imal notation Scan the END barcode NOTE For PDF 417 barcodes only the data character...

Page 147: ...7 continued Minimum Reads This feature specifies the minimum number of consecutive times a PDF 417 label must be decoded before it is accepted as good read START END PROGRAMMING BARCODES Minimum 1 Rea...

Page 148: ...s Advanced Decoding Features 6 6 Magellan 1000i Datamatrix Disable Enable Datamatrix When disabled the scanner will not read Datamatrix barcodes START END PROGRAMMING BARCODES Disable Datamatrix Enabl...

Page 149: ...Scan the END barcode 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 00 if there is only one...

Page 150: ...1 or Set Length 2 barcode 3 Turn to Alpha Numeric Pad and scan the four hex digits representing the length in hexidec imal notation Scan the END barcode NOTE For Datamatrix barcodes only the data char...

Page 151: ...x continued Minimum Reads This feature specifies the minimum number of consecutive times a Datamatrix label must be decoded before it is accepted as good read START END PROGRAMMING BARCODES Minimum 1...

Page 152: ...the host If the button is not pushed within 30 seconds the scanner will return to barcode reading scanning mode IMAGE CAPTURE Captured Image Format Images are captured as 752 x 480 JPEG format with a...

Page 153: ...r Dimensions Parameter Specification Scan Volume 80 cubic inches Scan Pattern 100 lines Scan Rate 1170 Digital Scan Lines second Minimum Resolution 5 mil Depth of Field 100 UPC Labels 0 8 Minimum Prin...

Page 154: ...Two Models 5V unit 5 0V 5 12V unit 8 14V 5 Input Current Operating idle Operating label read Surge Current 30 ms 350mA 450 mA 650mA Parameter Specification Mechanical Shock Multi 1 2m drops Contaminan...

Page 155: ...ble Pinouts Standard Cable Pinouts Primary Interface Cables RS 232 IBM Port 5B 9B 17 1 2 CTS 3 4 RTS 5 RXD 6 TXD 7 8 VCC IN 9 GND 10 1 2 3 4 DATA 5 6 DATA 7 8 VCC_IN 9 GND 10 Pin 1 10 Position RJ Scan...

Page 156: ...1 2 3 4 D 5 6 D 7 8 VIN 9 GND 10 1 2 3 4 D 5 6 D 7 8 VBUS_VIN 9 GND 10 1 2 3 WAND 4 5 6 7 8 VCC_IN 9 GND 10 1 2 KB_DATA 3 AT_CLK 4 KB_CLK 5 6 AT_DATA 7 8 VCC_IN 9 GND 10 Pin 1 10 Position RJ Scanner...

Page 157: ...Product Reference Guide C 1 Chapter C Alpha Numeric Pad A B C D E F...

Page 158: ...C 2 Magellan 1400i Alpha Numeric Pad 1 2 3 0 9 8 7 6 5 4...

Page 159: ...Sleep Mode 10 minutes 2 3 Power On Alert Enable 2 5 Good Read When to Indicate After Decode 2 6 Good Read Beep Control Enable 2 7 Good Read Beep Fre quency Medium 2 7 Good Read Beep Length 60 msec 2...

Page 160: ...Disable 3 13 Host Echo Disable 3 14 Host Echo Quiet Interval 10 msec 3 15 Signal Voltage Normal TTL Normal RS 232 3 16 RS 232 Invert Disable 3 17 Beep on ASCII BEL Enable 3 17 Beep on Not on File Enab...

Page 161: ...d Emulation Symbology Conversion Wand Emulation No Conversion 3 29 Keyboard Wedge USB Keyboard Keyboard Layout KBW USB KB USA 3 30 Keyboard Wedge USB Keyboard Caps Lock State KBW USB KB Disable 3 32 K...

Page 162: ...PC E w P5 Addon Label ID E 4 7 UPC E w C128 Addon Label ID E 4 7 EAN 8 Label ID FF Wincor Nixdorf B 4 7 EAN 8 w P2 Addon Label ID FF 4 7 EAN 8 w P5 Addon Label ID FF 4 7 EAN 8 w C128 Addon Label ID FF...

Page 163: ...r Nixdorf I 4 9 Codabar Label ID Wincor Nixdorf N 4 10 Code 93 Label ID Wincor Nixdorf L 4 10 MSI Plessey Label ID Wincor Nixdorf O 4 10 Std 2 of 5 Label ID i Wincor Nixdorf H 4 10 PDF 417 Label ID P...

Page 164: ...to GTIN Don t Expand 5 8 Disable Enable EAN 13 Enable 5 9 EAN 13 Check Digit Transmission Send Check Digit 5 9 EAN 13 Flag 1 Character Transmit 5 10 ISBN Disable 5 10 EAN 13 Minimum Reads 1 5 11 Disa...

Page 165: ...taBar Expanded 128 Emula tion Disable 5 19 GS1 DataBar Expanded Length Control Variable Length 5 20 GS1 DataBar Expanded Length 1 1 5 21 GS1 DataBar Expanded Length 2 74 5 21 GS1 DataBar Expanded Mini...

Page 166: ...ormat Disable 5 34 Code 128 Transmit Function Characters Don t Transmit 5 35 Code 128 Length Control Variable Length 5 36 Code 128 Length 1 1 5 37 Code 128 Length 2 80 5 37 Code 128 Conversion to Code...

Page 167: ...abar Quiet Zones Don t Require 5 48 Codabar Start Stop Character Type Start Stop Type abcd abcd 5 49 Codabar Start Stop Character Transmis sion Enable 5 49 Codabar Start Stop Character Match Disable 5...

Page 168: ...dard 2 of 5 Disable 5 62 Std 2 of 5 Check Digit Verification Disable 5 62 Std 2 of 5 Check Digit Transmit Enable 5 63 Std 2 of 5 Length Control Variable Length 5 64 Std 2 of 5 Length 1 8 5 65 Std 2 of...

Page 169: ...Standard Feature Defaults Product Reference Guide D 11 PDF417 Length 1 6 8 PDF417 Length 2 6 8 PDF417 Minimum Reads 6 9 Feature Std RS 232 Setting Interface Specific Exceptions Page...

Page 170: ...D 12 Magellan 1400i...

Page 171: ...T Scan Set 1 No No AT PS 2 25 286 PS 2 30 286 PS 2 50 50Z PS 2 60 70 80 90 95 Foreign ALT Mode Wedge B AT PS2 Scan Set 2 No No PS 2 25 and 30 Foreign ALT Mode Wedge C AT PS2 Scan Set 1 No No PC XT U S...

Page 172: ...C2 LEFT arrow inner keypad 4Bh E0 13 DC3 DOWN arrow inner keypad 50h E0 14 DC4 UP arrow inner keypad 48h E0 ASCII hex ASCII code Key Scancode 00 NUL ALT right Make E0h 11h 01 SOH ALT right Break E0h F...

Page 173: ...left Break F0h 11h 06 ACK CTRL right Make 58h 07 BEL CTRL right Break F0h 58h 08 BS BS 66h 09 HT TAB right 0Dh 0A LF RIGHT arrow inner keypad 6Ah 0B VT TAB left 0Dh S 0C FF Enter inner keypad 79h 0D C...

Page 174: ...Make Break 58h F0h 58h 08 BS BS 66h 09 HT TAB right 0Dh 0A LF RIGHT arrow inner keypad 6Ah 0B VT TAB left 0Dh S 0C FF CR FIELD EXIT Make only 5Ah F0h 5Ah 0D CR CR FIELD EXIT Make Break 5Ah 0E SO INSE...

Page 175: ...k C1h 08h BS BS 3Eh 09h HT TAB right 3Ch 0Ah LF RIGHT arrow inner keypad 4Dh 0Bh VT TAB left 3Ch S 0Ch FF Enter right keypad 60h 0Dh CR CR 3Bh 0Eh SO INSERT inner keypad 52h 0Fh SI PAGE UP inner keypa...

Page 176: ...ight 0Fh 0Ah LF RIGHT arrow inner keypad 3Ch 0Bh VT TAB left 0Fh S 0Ch FF DELETE 39h 0Dh CR CR 1Ch 0Eh SO INSERT inner keypad 38h 0Fh SI KATAKANA LOCK ON Make 72h 10h DLE KATAKANA LOCK OFF Break F2h 1...

Page 177: ...h Support for more details COMMAND ASCII HEX COMMENT Enable Scanner E 0x45 Disable Scanner D 0x44 Reset Scanner R 0x52 Not On File Indication F 0x46 Long series of beeps Beep Good Read Tone B 0x42 Bee...

Page 178: ...F 2 Magellan 1400i NOTES...

Page 179: ...t Reference Guide G 1 Chapter G Sample Symbols 0 1234567890 1234567890 Code 128 9 780330 290951 BC321 123456 9 123456 UPC A Code 128 Code 39 Code 93 Interleaved 2 of 5 EAN 13 Code 2 of 5 A13579B Codab...

Page 180: ...G 2 Magellan 1400i Sample Symbols 01 00123456789012 GS1 DataBar Omnidirectional 0100123456789050 GS1 DataBar Expanded...

Page 181: ...Product Reference Guide G 3 NOTES...

Page 182: ...G 4 Magellan 1400i NOTES...

Page 183: ...14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V...

Page 184: ...Datalogic Scanning KK Telephone 81 0 3 3491 6761 japan scanning datalogic com Latin America Datalogic Scanning Inc Telephone 305 591 3222 latinamerica scanning datalogic com Singapore Datalogic Scann...

Reviews: