PDF 417
Code
Parameter
Description
I.D.#
Accept.
Input
Defaults
Scanner
Type
Mi
n
Max
Factory
2D Image
r
Enter 1 for On and 0 for Off
PDF-417
Enable
Enables/disables the PDF
417 symbology
.
0A00
On or Off
Off
On
On
√
PDF-417
Minimum
Set the minimum bar code
label length to be less
than or equal to maximum
label length.
0A20
1 - 2710
1
2710
1
√
PDF-417
Maximum
This feature specifies the
maximum allowable length
of a label. The length
includes check and data
characters, if applicable.
Maximum Label Length
should be greater than or
equal to Minimum Label
Length.
0A21
1 - 2710
1
2710
2710
√
PDF-417
User Code ID
Specifies the symbology
identifier (if any) that is
sent when parameter
Send Code ID (Index
0025) is set to 3. ASCII
code zero (null) is used to
indicate that an identifier
is not to be sent for the
symbology.
0A23
Any
single
ASCII
character
(00 = Off)
‘S’ ‘S’ ‘S’
√