European Article Numbering-8 (EAN-8)
Code
Parameter
Description
I.D.#
Accept.
Input
Defaults Scanner
Type
Mi
n
Max
Factory
Laser
2D Image
r
Lor
ax
Enter 1 for On and 0 for Off
Enable
Enables/disables the EAN-
8 symbology.
0518
On or Off
Off
On
On
√
√
√
Enable
Aggressive
Decoding
Enables more aggressive
decoding algorithms to be
used in order to scan hard
to read labels.
0519
On or Off
Off
On
Off
√
√
Send
Check Digit
Instructs the terminal to
include the check digit in
the label transmission.
051A
On or Off
Off
On
Off
√
√
√
Convert EAN-8
to EAN-13
Instructs the decoder to
expand EAN-8 labels to
their EAN-13 equivalents.
Any EAN-13 parameters
will then apply to the result.
051B
On or Off
Off
On
Off
√
√
√
Read
Verification
Sets the number of times a
label must be read before
it is transmitted.
0526
01 - 04
01
02
01
√
User ID
Specifies the symbology
identifier (if any) that is
sent by the decoder when
parameter Send Code ID
(Index 0025) is set to 3.
ASCII code zero (null) is
used to indicate that an
identifier is not to be sent
for the symbology.
0527
Any
single
ASCII
character
(00 = Off)
‘G’
‘G’
‘G’
√
√
√
Summary of Contents for Lynx 00N0LD-1N0-MEN0
Page 28: ...NOTE ...
Page 39: ...Remove the protective film cover over the Laser Output Window before use NOTE ...
Page 43: ...Numeric Keyboard ...
Page 131: ...Code 128 ÌtestwÎ test 120 EAN 13 x 0B2DE5 KKKKLM 120 EAN 8 6450 TRMN ...
Page 132: ...2D Codes Datamatrix ECC200 Example Inverse Datamatrix ECC200 Example ...
Page 185: ...T Data Capture Laser Output Window U Handylink Connector host slave ...
Page 188: ......