background image

 

 

DS4600A QUICK GUIDE 

 

10  

 

 

 

DS4600A-32XX (Short Range) 

CONDITIONS 

Code = Interleaved 2/5 and Code 39 
PCS = 0.90 
"Pitch" angle = 0° 
"Skew" angle = 15° 
"Tilt" angle = 0° 
*SW Resolution: High 
 
 
* Parameter selectable in WinHost. 

 

 

 

-2 

10 

-4 

-6 

-8 

-10 

(in) 

0

2

6

4

20 

12

(in)

8

10

14 16 18 

0

40

80 120 160 200 240 280 320 360  400  440  480  520

(mm)

240

200

160

120

80

40

0

-40

-80

-120

-160

-200

-240

(mm)

0.20 mm 

(8 mils) 

0.25 mm 

(10 mils) 

 0.30 mm

(12 mils) 

 

 

Summary of Contents for Laser Barcode Reader DS4600A-2XX5

Page 1: ...UTPUT RADIATION 1 mW EMITTED WAVE LENGTH 630 680 nm TO EN 60825 1 2001 Warning and device class labels Power Supply This product is intended to be installed by Qualified Personnel only Models DS4600A...

Page 2: ...93 Codabar Auxiliary Interface RS232 Pharmacode Baudrates 1200 to 115200 Inputs Headers and Up to four header and four External Trigger IN1 IN2 optocoupled NPN or PNP Terminators terminator character...

Page 3: ...d through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0 8 Vdc The details of the connector pins are indicated in the following table 25 pin D sub female con...

Page 4: ...t Output Connections Open Collector USER INTERFACE 8 11 12 22 DS4600A 25 pin Vext 40 Vdc max C E Output open collector connections VCE max 40 Vdc I max 40 mA continuous NPN NPN 5V DS4600A 25 pin USER...

Page 5: ...rial Interface RS485 Half Duplex dAuxiliary Serial Interface RS232 dAuxiliary Serial Interface Local Echo RS232 eExternal Trigger for On Line Mode eExternal Trigger for On Line Mode RS232 Master slave...

Page 6: ...0 300 400 mm 24 28 32 36 40 16 8 8 0 50 mm 20 mils 0 60 mm 24 mils 0 80 mm 31 mils 1 00 mm 40 mils DS4600A 200X Medium Range CONDITIONS Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch angle 0 Skew angl...

Page 7: ...240 260 mm 120 100 80 60 40 20 0 20 40 60 80 100 120 mm 280 11 0 20 mm 8 mils 0 30 mm 12 mils DS4600A 22XX Short Range CONDITIONS Test Codes used Interleaved 2 5 and Code 39 PCS 0 90 Pitch angle 0 Ske...

Page 8: ...0 550 mm 250 200 150 100 50 0 50 100 150 200 250 mm 20 22 0 25 mm 10 mils 0 30 mm 12 mils 0 50 mm 20 mils 8 10 DS4600A 2X2X Raster R2 CONDITIONS Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch angle 0...

Page 9: ...24 28 32 36 40 16 8 8 0 50 mm 20 mils 0 60 mm 24 mils 0 80 mm 31 mils 1 00 mm 40 mils DS4600A 30XX Medium Range CONDITIONS Code Interleaved 2 5 and Code 39 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt an...

Page 10: ...Pitch angle 0 Skew angle 15 Tilt angle 0 SW Resolution High Parameter selectable in WinHost 4 2 0 2 10 8 6 4 6 8 10 in 0 2 6 4 20 12 in 8 10 14 16 18 0 40 80 120 160 200 240 280 320 360 400 440 480 52...

Page 11: ...8 CTS 5 CTS How To Build A Simple Interface Test Cable The following wiring diagram shows a simple test cable including power external push button trigger and PC RS232 COM port connections 25 pin D su...

Page 12: ...ompatibility and product safety Bas e sur la l gislation des Etats membres relative la compatibilit lectromagn tique et la s curit des produits ber die Ann herung der Gesetze der Mitgliedsstaaten in b...

Reviews: