background image

 

HF-CNTL-IND- 0 2   I N S T A L L A T I O N   G U I D E   –   R E V . 0 5               P A G E   1 4   O F   2 1

 

2.4

 

C

AB LI NG  

I

NF O RM AT I O N

 

 

Figure 2-1: 4-Pin, Female, M12, Connector (Ethernet) & 5-Pin, Male, M12 Connector 

(Power) 

 

4-P

IN 

F

E MALE 

M12

 

D-C

ODE 

C

O NNECT OR 

-

 

E

TH ERNET

 

PIN # 

DESCR IPT ION 

Tx+ 

Rx+ 

Tx- 

Rx- 

Table 2-2: 4-Pin, Female, M12, D-Code Connector (Ethernet) 

5-P

IN 

M

ALE 

M12

 

C

ON N ECTOR 

-

 

P

OWER

 

PIN # 

DESCR IPT ION 

NOT CONNECTED 

VDC PWR 

0VDC (POWER GND) 

NOT CONNECTED 

NOT CONNECTED 

Table 2-3: 5-Pin, Male, M12 Connector (Power) 

 

 

Summary of Contents for HF-CNTL-IND-02

Page 1: ...T HF CNTL IND 02 RFID CONTROLLER High Frequency Passive Radio Frequency Identification Controller INSTALLATION GUIDE How to Install and Setup Cobalt HF CNTL IND 02 RFID Controller HF CNTL IND 02 INSTA...

Page 2: ...e reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with...

Page 3: ...re pays pour v rifier d ventuelles restrictions ou licences Pour tout renseignement vous pouvez vous adresser au site web http ec europa eu enterprise sectors rtte DEUTSCH Wenden Sie sich an die f r R...

Page 4: ...requirements of the industrial automation industry 1 1 1 Package Contents Unpack the Cobalt Controller hardware and accessories Retain the original shipping carton and packing material in case any it...

Page 5: ...Connection Type Ethernet Communication Interface TCP IP Ethernet IP Modbus TCP Data Interface Connector 4 Pin Female M12 D Code for Ethernet data Power Interface Connector 5 pin Male M12 for power Ma...

Page 6: ...ecause Cobalt HF Antennas are designed with different dimensions they each generate unique RF field pattern and read write range Figure 1 2 Cobalt HF Series RFID Antennas COBALT HF RFID ANTENNAS MODEL...

Page 7: ...HF CNTL IND 0 2 I N S T A L L A T I O N G U I D E R E V 0 5 P A G E 7 O F 2 1 1 2 1 HF ANT 1010 01 Antenna Dimensions Figure 1 3 HF ANT 1010 01 Antenna Dimensions...

Page 8: ...HF CNTL IND 0 2 I N S T A L L A T I O N G U I D E R E V 0 5 P A G E 8 O F 2 1 1 2 2 HF ANT 2020 01 Antenna Dimensions Figure 1 4 HF ANT 2020 01 Antenna Dimensions...

Page 9: ...HF CNTL IND 0 2 I N S T A L L A T I O N G U I D E R E V 0 5 P A G E 9 O F 2 1 1 2 3 HF ANT 3030 01 Antenna Dimensions Figure 1 5 HF ANT 3030 01 Antenna Dimensions...

Page 10: ...HF CNTL IND 0 2 I N S T A L L A T I O N G U I D E R E V 0 5 P A G E 1 0 O F 2 1 1 2 4 HF ANT 0750 01 Antenna Dimensions Figure 1 6 HF ANT 0750 01 Antenna Dimensions...

Page 11: ...interference or near devices that generate high ESD electro static discharge levels If electrical interference is encountered as indicated by a reduction in read write performance relocate the contro...

Page 12: ...enna HF ANT 1010 01 3 2 Washer Spring Lock M5 18 8 SS 4 2 Screw Socket Head Cap M5 X 20mm 18 8 SS 2 2 1 Minimum Distance between Antennas When installing multiple Cobalt HF Series Controllers Antennas...

Page 13: ...crews through antenna s mounting holes and secure them with appropriate washers and nuts Tighten screws to 1 7 Nm or 15 lbs per inch 10 4 Connect the three wires from your power supply to pins 1 3 on...

Page 14: ...tor Ethernet 5 Pin Male M12 Connector Power 4 PIN FEMALE M12 D CODE CONNECTOR ETHERNET PIN DESCRIPTION 1 Tx 2 Rx 3 Tx 4 Rx Table 2 2 4 Pin Female M12 D Code Connector Ethernet 5 PIN MALE M12 CONNECTOR...

Page 15: ...dditional connector is placed in the bottom plate on the right side of normal connectors 8 PIN REVERSE KEYED FEMALE DIGITAL I O CONNECTOR Figure 2 2 8 Pin Reverse Keyed Female Digital I O Connector PI...

Page 16: ...IND 0 2 I N S T A L L A T I O N G U I D E R E V 0 5 P A G E 1 6 O F 2 1 Figure 2 3 CBL 1487 5 Pin Female M12 Straight Field Mountable Connector Figure 2 4 CBL 1515 05 5 Pin Male Ethernet M12 D Code C...

Page 17: ...ID Controllers Operator s Manual available online at www ems rfid com Also available online at www ems rfid com is Escort Memory Systems Cobalt Dashboard software utility The RFID Dashboard is a Windo...

Page 18: ...Range 12 30VDC DC Input Current 500 300mA RADIO Frequency 13 56MHz Air Interface ISO15693 ISO14443 Conducted Output Power 1W COMMUNICATION HF CNTL IND 02 10 100Mbit s Ethernet IP MODBUS TCP TCP IP Max...

Page 19: ...erature 20 to 50 C 4 to 122 F Storage Temperature 20 to 70 C 4 to 158 F Humidity 90 non condensing Protection Class IP65 3 2 HF ANTENNAS ELECTRICAL All models Frequency 13 56MHz Input Impedence 50 ohm...

Page 20: ...9 88oz HF ANT 2020 1 Dimensions 200x200x42mm 7 87x7 87x1 67in Weight 500g 17 64 oz HF ANT 3030 1 Dimensions 300x300x42mm 11 81x11 81x1 67 oz Weight 740g 26 10 oz HF ANT 0750 1 Dimensions 70x500x42mm 2...

Page 21: ...entation agreement or understanding oral or written made by an agent distributor representative or employee of Datalogic Automation which is not contained in this warranty will be binding upon Datalog...