2.1

 

P

R EP A RI N G  F O R  

I

NS TA L LA TI O N

 

2.1.1  Power Requirements 

The  Cobalt  Controller  requires  an  electrical  DC  supply  voltage.  See  Technical 

Specifications for details. Use a dedicated and regulated power supply connected to a 

suitable  AC  power  source  that  is  capable  of  delivering  these  requirements.  Do  not 

apply power until the entire system is wired and checked.  

2.1.2  Installation Guidelines 

 

RF performance and read/write range can be negatively impacted by the 

proximity of metallic objects. Avoid mounting the antenna within 15cm (6 

inches) of any metallic object or surface. 

 

Do not route cables near unshielded cables or near wiring carrying high 

voltage or high current. Cross cables at perpendicular intersections and 

avoid routing cables near motors and solenoids. 

 

Avoid mounting the controller near sources of EMI (electro-magnetic 

interference) or near devices that generate high ESD (electro-static 

discharge) levels.  

 

If electrical interference is encountered (as indicated by a reduction in 

read/write performance), relocate the controller to an area free from 

potential sources of interference.  

 

Conduct a test phase where you will construct a small scale, independent 

network that includes only the essential devices required to test your RFID 

application. To avoid possible interference with other devices, do not initially 

connect your RFID testing environment to an existing local area network.  

 

Always use adequate ESD prevention measures to dissipate potentially high 

voltages. 

 

 

 

2.2

 

C

O N N EC TI N G  TH E  

A

NT E NN A

 

Cobalt HF-Series RFID Antennas mount directly to the top of the Cobalt HF-Series 

RFID Controller’s housing. The antenna is first attached to the RF port on the 

controller and is then fastened to the controller’s housing using the two M5 screws and 

matching spring lock washers included with each Cobalt HF-Series RFID Controller. 

Use the provided 4mm hex key wrench to tighten both M5 screws. 

T

ORQ UE 

S

PEC IF ICAT IO N

 

Screws should be tightened to the following torque setting: 

Summary of Contents for HF-CNTL-IND-02

Page 1: ...T HF CNTL IND 02 RFID CONTROLLER High Frequency Passive Radio Frequency Identification Controller INSTALLATION GUIDE How to Install and Setup Cobalt HF CNTL IND 02 RFID Controller HF CNTL IND 02 INSTA...

Page 2: ...e reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with...

Page 3: ...re pays pour v rifier d ventuelles restrictions ou licences Pour tout renseignement vous pouvez vous adresser au site web http ec europa eu enterprise sectors rtte DEUTSCH Wenden Sie sich an die f r R...

Page 4: ...requirements of the industrial automation industry 1 1 1 Package Contents Unpack the Cobalt Controller hardware and accessories Retain the original shipping carton and packing material in case any it...

Page 5: ...Connection Type Ethernet Communication Interface TCP IP Ethernet IP Modbus TCP Data Interface Connector 4 Pin Female M12 D Code for Ethernet data Power Interface Connector 5 pin Male M12 for power Ma...

Page 6: ...ecause Cobalt HF Antennas are designed with different dimensions they each generate unique RF field pattern and read write range Figure 1 2 Cobalt HF Series RFID Antennas COBALT HF RFID ANTENNAS MODEL...

Page 7: ...HF CNTL IND 0 2 I N S T A L L A T I O N G U I D E R E V 0 5 P A G E 7 O F 2 1 1 2 1 HF ANT 1010 01 Antenna Dimensions Figure 1 3 HF ANT 1010 01 Antenna Dimensions...

Page 8: ...HF CNTL IND 0 2 I N S T A L L A T I O N G U I D E R E V 0 5 P A G E 8 O F 2 1 1 2 2 HF ANT 2020 01 Antenna Dimensions Figure 1 4 HF ANT 2020 01 Antenna Dimensions...

Page 9: ...HF CNTL IND 0 2 I N S T A L L A T I O N G U I D E R E V 0 5 P A G E 9 O F 2 1 1 2 3 HF ANT 3030 01 Antenna Dimensions Figure 1 5 HF ANT 3030 01 Antenna Dimensions...

Page 10: ...HF CNTL IND 0 2 I N S T A L L A T I O N G U I D E R E V 0 5 P A G E 1 0 O F 2 1 1 2 4 HF ANT 0750 01 Antenna Dimensions Figure 1 6 HF ANT 0750 01 Antenna Dimensions...

Page 11: ...interference or near devices that generate high ESD electro static discharge levels If electrical interference is encountered as indicated by a reduction in read write performance relocate the contro...

Page 12: ...enna HF ANT 1010 01 3 2 Washer Spring Lock M5 18 8 SS 4 2 Screw Socket Head Cap M5 X 20mm 18 8 SS 2 2 1 Minimum Distance between Antennas When installing multiple Cobalt HF Series Controllers Antennas...

Page 13: ...crews through antenna s mounting holes and secure them with appropriate washers and nuts Tighten screws to 1 7 Nm or 15 lbs per inch 10 4 Connect the three wires from your power supply to pins 1 3 on...

Page 14: ...tor Ethernet 5 Pin Male M12 Connector Power 4 PIN FEMALE M12 D CODE CONNECTOR ETHERNET PIN DESCRIPTION 1 Tx 2 Rx 3 Tx 4 Rx Table 2 2 4 Pin Female M12 D Code Connector Ethernet 5 PIN MALE M12 CONNECTOR...

Page 15: ...dditional connector is placed in the bottom plate on the right side of normal connectors 8 PIN REVERSE KEYED FEMALE DIGITAL I O CONNECTOR Figure 2 2 8 Pin Reverse Keyed Female Digital I O Connector PI...

Page 16: ...IND 0 2 I N S T A L L A T I O N G U I D E R E V 0 5 P A G E 1 6 O F 2 1 Figure 2 3 CBL 1487 5 Pin Female M12 Straight Field Mountable Connector Figure 2 4 CBL 1515 05 5 Pin Male Ethernet M12 D Code C...

Page 17: ...ID Controllers Operator s Manual available online at www ems rfid com Also available online at www ems rfid com is Escort Memory Systems Cobalt Dashboard software utility The RFID Dashboard is a Windo...

Page 18: ...Range 12 30VDC DC Input Current 500 300mA RADIO Frequency 13 56MHz Air Interface ISO15693 ISO14443 Conducted Output Power 1W COMMUNICATION HF CNTL IND 02 10 100Mbit s Ethernet IP MODBUS TCP TCP IP Max...

Page 19: ...erature 20 to 50 C 4 to 122 F Storage Temperature 20 to 70 C 4 to 158 F Humidity 90 non condensing Protection Class IP65 3 2 HF ANTENNAS ELECTRICAL All models Frequency 13 56MHz Input Impedence 50 ohm...

Page 20: ...9 88oz HF ANT 2020 1 Dimensions 200x200x42mm 7 87x7 87x1 67in Weight 500g 17 64 oz HF ANT 3030 1 Dimensions 300x300x42mm 11 81x11 81x1 67 oz Weight 740g 26 10 oz HF ANT 0750 1 Dimensions 70x500x42mm 2...

Page 21: ...entation agreement or understanding oral or written made by an agent distributor representative or employee of Datalogic Automation which is not contained in this warranty will be binding upon Datalog...

Reviews: