Enter Configuration
Exit and Save Configuration
Ì$+;Î
DATA FORMAT
Ì$-?Î
67
F
IELD
A
DJUSTMENT
disable field adjustment
ÌEF0[Î
Field adjustment allows a number of characters
n
, to be added to or subtracted from the
barcode read. The adjustment can be different for each enabled code type. To define the field
adjustment:
c
Read the enable field adjustment code:
enable field adjustment
ÌEF+Î
d
Select the code type from the Code Identifier Table in Appendix
.
e
Select the type of adjustment to perform:
right addition
Ì01Î
left addition
right deletion
Ì12Î
Ì23Î
left deletion
Ì34Î
f
Read a number in the range
01 - 32
from the Hex/Numeric Table to define how many
characters to add or delete:
Conditions:
•
Adjustment is only performed on the barcode data, the Code Identifier and Code Length
Transmission fields are not modified by the field adjustment parameter.
•
If the field setting would subtract more characters than exist in the barcode, the subtraction
will take place only to code length 0.
•
You can set up to a maximum of 10 different field adjustments on the same barcode family
or on different barcode families.
Example:
To add 4 characters to the right of Standard Code 39 Codes:
enable field adjustment
Code 39
right addition
Read
ÌEF+Î
+
ÌVWÎ
+
Ì01Î
+
04
Summary of Contents for GRYPHON
Page 12: ...GRYPHON 4 2 3 RS232 CONNECTION 2 4 USB ...
Page 13: ...INSTALLATION 5 2 5 IBM USB POS 2 6 WEDGE CONNECTION ...
Page 14: ...GRYPHON 6 2 7 PEN EMULATION CONNECTION ...
Page 67: ...59 ...
Page 76: ...Enter Configuration Exit and Save Configuration Ì Î DATA FORMAT Ì Î 68 ...
Page 86: ...Enter Configuration Exit and Save Configuration Ì Î POWER SAVE Ì Î 78 ...
Page 98: ...90 ...
Page 120: ...Enter Configuration Exit and Save Configuration Ì Î CODE SELECTION Ì Î 112 ...
Page 138: ...Exit and Save Configuration ADVANCED FORMATTING Ì Î 130 end Format 4 definition ÌHM3uÎ ...