GRYPHON™
156
5.10.3 Copy OM-GRYPHON™
Procedure:
c
Using the
slave
reader and its OM-Gryphon™ cradle, read the Restore Default
barcode, set the radio address, and then read the RS232 interface barcode
from chapter
of this manual or from the Quick Reference Manual.
d
Connect the
master
OM-Gryphon™ and the
slave
OM-Gryphon™ (cradle to be
configured) together through two RS232 serial interface cables and external
power supply. Accessory cables and power supply are available from your
Datalogic distributor to provide this connection.
RS232 Cables: CAB363 & CAB364 or CAB320 & CAB328
Power Supply: PG12
e
Read the Configuration Copy barcode below with a reader. Then place it onto
the
master
OM-Gryphon™ cradle.
Copy Configuration
Ì$+ZZ3$-9Î
The configuration will be copied from the master OM-Gryphon™ to the slave
OM-Gryphon™. The reader signals the end of the procedure with a series of beeps.
f
Repeat the procedure above to configure other slave cradles.
Note:
The master OM-Gryphon™ can be configured for any interface.
Summary of Contents for GRYPHON
Page 12: ...GRYPHON 4 2 3 RS232 CONNECTION 2 4 USB ...
Page 13: ...INSTALLATION 5 2 5 IBM USB POS 2 6 WEDGE CONNECTION ...
Page 14: ...GRYPHON 6 2 7 PEN EMULATION CONNECTION ...
Page 67: ...59 ...
Page 76: ...Enter Configuration Exit and Save Configuration Ì Î DATA FORMAT Ì Î 68 ...
Page 86: ...Enter Configuration Exit and Save Configuration Ì Î POWER SAVE Ì Î 78 ...
Page 98: ...90 ...
Page 120: ...Enter Configuration Exit and Save Configuration Ì Î CODE SELECTION Ì Î 112 ...
Page 138: ...Exit and Save Configuration ADVANCED FORMATTING Ì Î 130 end Format 4 definition ÌHM3uÎ ...