![Datalogic DX8200A Reference Manual Download Page 90](http://html1.mh-extra.com/html/datalogic/dx8200a/dx8200a_reference-manual_511923090.webp)
DX8200A
7
SOFTWARE FEATURES
Readable Codes
Interleaved 2/5
Code 39 Standard
Codabar
Code 128
EAN 128
Code 93 (standard and full ASCII)
EAN/UPC (including Add-on 2 and Add-on 5)
Code selection
Up to 10 codes during one reading phase
Headers and Terminators
Up to 128-byte headers and 128-byte terminators
Operating modes
On Line, Serial On Line, Automatic, Test,
PackTrack™, Continuous
Configuration modes
Genius™ utility program
Parameter storage
Non-volatile internal FLASH
ENVIRONMENTAL FEATURES
Operating temperature
0° to +50 °C (+32° to +122 °F)
Storage temperature
-20° to +70 °C (-4° to +158 °F)
Humidity
90% non condensing
Ambient light immunity
20000 lux
Vibration resistance:
EN 60068-2-6
2 hours on each axis
Frequency range from 5 to 150 Hz;
Constant displacement 3 mm pk-pk from 5 to 9 Hz;
Constant acceleration 0.5 g from 9 to 150 Hz
Shock resistance:
IEC 68-2-27 test EA
3 shocks on each axis
30 g; 11 ms
VAC models
VDC models
Protection class
IP54*
IP64*
PHYSICAL FEATURES
Mechanical dimensions
470 x 300 x 141 mm (18.50 x 11.81 x 5.55 in)
Weight
about 11 kg (24 lbs. 3 oz)
* sealed connectors required; use Harting RJ Industrial® Push Pull Ethernet connector for Ethernet
models.
74