![Datalogic DX8200A Reference Manual Download Page 40](http://html1.mh-extra.com/html/datalogic/dx8200a/dx8200a_reference-manual_511923040.webp)
DX8200A
2
2.3.5 Profibus
Connector
The 9-pin Profibus female connector (white) is only available in the DX8200A Profibus model
and allows connection between the host and the reader:
5
1
9
6
Figure 28 - Profibus 9-pin Female Connector
DX8200A 9-pin Profibus connector pinout
Pin Name
Function
1
Shield*
Shield, Protective Ground resp.
2 Free
3
B-LINE (RxD/TxD-P)
Received/Transmitted Data-P
4
CNTR-P**
Repeater Control Signal
5
DGND
Data Ground (M5V)
6
+5 V
Voltage Plus (P5V)
7 Free
8
A-LINE (RxD/TxD-N)
Received/Transmitted Data
9
CNTR-N**
Repeater Control Signal
*
signal is optional
** signal is optional; RS485 level
Profibus Interface
The Profibus interface is used for communication with an Host and allows expanding the
networking and remote diagnostic capabilities of the scanner.
For further details refer to the “Profibus_Fam6k.pdf” document provided as supplementary
documentation.
2.3.6 Power
Supply
Vdc models:
The supply voltage for correct operation of the scanner must be between 20 and 30 VDC.
The max. power consumption is 35 W including startup current.
Several accessory power supplies are available to power the DX8200A VDC models and
reading station components. See par. 1.5.
A security system allows the laser to activate only once the motor has reached the correct
rotational speed; consequently, the laser beam is generated after a slight delay from the
power on of the scanner.
24