![Datalogic DX8200A Reference Manual Download Page 47](http://html1.mh-extra.com/html/datalogic/dx8200a/dx8200a_reference-manual_511923047.webp)
INSTALLATION
2
2.5.4 Multiplexer
The Multiplexer connection is used to integrate a DX8200A slave reader in a Multidrop
network consisting of different scanners not provided with a Lonworks interface.
Each scanner is connected to a Multiplexer (MX4000) with the RS485
half-duplex main interface.
EN
T
<
<
EN
T
<
<
P.S.*
P.S.*
P.S.*
DX8200A
DS4600A
DS4600A
PWR-120
C
C
C
-BOX 100
-BOX 100
-BOX 100
MX4000
#0
#1
1
#31
Local Host
1
RS485 HD Main Interface
* P.S. (Presence Sensor) connected to External Trigger/PS input.
Figure 37 – Multiplexer for DX8200A Standard Models
The auxiliary serial interface of the slave scanners can be used to visualize collected data or
to configure it using the Genius™ utility.
When On-Line operating mode is used, the scanner is activated by an External Trigger when
the object enters its reading zone.