background image

MTBF Prediction (Calculated)

22

DSE0420

System Model:

• All assemblies in serial mode. All assemblies must function for the sys-

tem to work.

Assembly Calculation Criteria:

• All Electronic assembly failure rates calculated from BOM listing using 

Telcordia model.

DATALOGIC HAS DEMONSTRATED A 99% SUCCESS RATE OF MEETING OR 

EXCEEDING OUR PREDICTION BASED ON ACTUAL PRODUCT DEMONSTRATED 

LIFE TEST RESULTS AND ACTUAL FIELD DATA.

Any requests for reliability information on our products are granted with a 

clear understanding that MTBF/RAMM numbers are design targets. They are 

based on all available reliability data from preceding product demonstrated 

life testing and calculated semiconductor failure rates. They do not repre-

sent an implied warranty. As with all reliability numbers, infant mortality, 

early wear-out failures and variations in operating environment are not 

included.

Date: 5-June-2013

Reliability Engineer: D.A. Hershberger

Summary of Contents for DSE0420

Page 1: ...DSE0420 Integration Guide OEM Area Imager Decoded Scan Engine ...

Page 2: ...presentative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publi cations please let us know via the Contact Datalogic page Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is...

Page 3: ...Exit Window Recommendations 7 Avoiding scratched windows 7 Window material 7 Exit window properties 7 ELECTRICAL INTEGRATION 9 Overview 9 Host Connector Configuration 10 HW_TRIGGER Signal 11 Software TRIGGER Commands 11 SOFTWARE FEATURES 13 USB KB interface 13 USB COM driver and how it relates to the two interfaces 13 Firmware and configuration updates 14 QUALITY AND RELIABILITY 17 REGULATORY SAFE...

Page 4: ...ii DSE0420 NOTES ...

Page 5: ...nts when applied to the Software shall mean acquire under license Integrator is not entitled to receipt or use of the source code to any Software 2 2 Integrator shall not modify decompile disassemble reverse engineer or otherwise reproduce or remanu facture the Software whether modified or unmodified nor sell assign sublicense distribute lend rent give or other wise transfer the Software separatel...

Page 6: ...ID BY INTEGRATOR FOR THE DATALOGIC PROD UCT UNDER NO CIRCUMSTANCES SHALL DATALOGIC BE LIABLE TO INTEGRATOR OR ANY THIRD PARTY FOR LOST PROFITS LOST DATA INTERRUPTION OF BUSINESS OR SERVICE OR FOR ANY OTHER SPECIAL CONSE QUENTIAL CONTINGENT INDIRECT INCIDENTAL PUNITIVE EXEMPLARY OR OTHER SIMILAR DAMAGES EVEN IF DATALOGIC HAS BEEN ADVISED OF THE POSSIBIL ITY OF SUCH DAMAGES 9 Government Restricted R...

Page 7: ... for properly diagnosing repairing and operating the reader CAUTION The CAUTION symbol advises you of actions that could damage equipment or property Outline Preface this chapter presents information about manual conventions and contact data Chapter 1 Mechanical Characteristics provides information about physical and performance characteristics Chapter 2 Optical Characteristics Chapter 3 Electrica...

Page 8: ...ons for returning products for repair Reseller Technical Support An excellent source for technical assistance and information is an autho rized Datalogic reseller A reseller is acquainted with specific types of busi nesses application software and computer systems and can provide individualized assistance Telephone Technical Support If you do not have internet or email access you may contact Datal...

Page 9: ...odule Decoder board DSE0420 SCAN ENGINE Host connector RAM Microprocessor Beeper connector Beeper board Aim projector Receiving optics Illuminator Green Spot projector cable is shown for reference only it is not included in the assembly and must be provided by the integrator ...

Page 10: ...in the assembly and must be provided by the integrator Key Parameters Dimensions See Mechanical Drawings starting on page 23 for further details on mechanical features Parameter Value Weight DSE0420 20 g Max Height Beeper board not included 13 65 mm Max Width Beeper board not included 40 10 mm Max Length Beeper board not included 47 86 mm ...

Page 11: ...52H x 480V Illumination System LED source White emission wavelength 400 750 nm IEC 62471 EXEMPT RISK GROUP Aiming System Laser source Red emission wavelength 630 680 nm Pulsed source maximum lamp duration 15ms repetition rate 16 6 ms Maximum emitted power 1 mW IEC 60825 CLASS 2 LASER PRODUCT Tilt Tolerance Up to 360 Pitch Tolerance 65 Skew Tolerance 60 Field of View 40 H x 26 V ...

Page 12: ...and related optics It projects a highly visible 4 Dot aimer with center cross for targeted scan ning Aiming Pattern The central cross represents the center of the field of view while the four dots show the boundaries of the field of view Figure 1 Projected pattern at 200 mm Aiming System Parameters Wavelength 630 680 nm Beam Divergence 35 horizontal x 25 vertical see drawings on page 25 Maximum pu...

Page 13: ...ntarily causes no known biological damage avoid staring at the beam as one would with any very strong light source such as the sun Avoid that the laser beam hits the eye of an observer even through reflective surfaces such as mirrors etc ATTENTION NORMES DE SECURITE LASER Ce produit est conforme aux normes de sécurité laser en vigueur à sa date de fabri cation CDRH 21 CFR 1040 et EN60825 1 Il n es...

Page 14: ... 1 see Test Conditions below Note 2 for additional information on exit window disposal see Appendix B of this docu ment Test Conditions All distances are taken on axis from the illumination lenses at the following typical conditions in open air means without any interposed transparent or semi trans parent material environmental light 300 lux Pitch angle 10 Skew angle 0 Tilt angle 10 1D labels 0 2D...

Page 15: ...ials Optical Quality Very good Very good Surface Hardness Hard coating required Hard coating required Impact Resistance Good Good Chemical UV Resistance Susceptible Susceptible Ultrasonically Welding Compatible Compatible Exit window properties Recommended properties performance of the exit window are reported in Table 2 Table 2 Exit Window Properties Material PMMA or CR39 or equivalent Thickness ...

Page 16: ...Optical Characteristics 8 DSE0420 NOTES ...

Page 17: ...rge at Start up Measured at first cold plug in 35 μC Stand by Scan Mode Trigger Single 12 mA Operative Acquiring w o Beeping Scan Mode Trigger Single Flashing 80 150 200 mA Operative Object Detection Scan Mode Stand Mode 70 90 110 mA Operative Acquiring w o Beeping Scan Mode Stand Mode 60 150 230 mA Operative while Beeping Scan Mode Trigger Single 40 150 260 mA Operative while Beeping Scan Mode Fl...

Page 18: ...coder side connector pinout USB Hub Deco der 8 POWER_ON Connected to BJT Base with the following net Leave unconnected if not used 7 HW_TRIGGER Connected to BJT Base with the following net Leave unconnected if not used 6 VBUS External power supply 5V 5 electrically shorted to Pin 5 5 VBUS External power supply 5V 5 electrically shorted to Pin 6 4 GND 0V reference electrically shorted to Pin 1 3 US...

Page 19: ...ammed to the Decoder before to use it The current default configuration is Trigger Single In the following pictures PRESS and RELEASE words refer to the common meaning of pressing a push button and releasing it in order to obtain a spe cific behavior The current release of the Decoder board has the HW_TRIG GER signal with the following level meaning Software TRIGGER Commands The PRESS and RELEASE ...

Page 20: ...Electrical Integration 12 DSE0420 NOTES ...

Page 21: ...USB COM driver and how it relates to the two interfaces The DL USB COM driver is supplied by Datalogic and provides legacy appli cations the ability to connect to a virtual COM port enumerated by the device during connection to the PC The driver also provides certain config uration capabilities when used with other Datalogic software When used with the Composite USB interface where the device enum...

Page 22: ... and configuration files can be updated on the scanner module when the module is in the USB COM or Composite interface Updating firm ware or configuration is not a common operation and will only be performed upon occasions where new firmware is required or a specific customer requires special configuration of the module When an update is needed the tablet image will come pre loaded with soft ware ...

Page 23: ... are installed scanner_name IntegratedImagingBarcodeScanner path filename the path to the update file update file name 3 Limitations The module must be in USB COM or Composite interface updates are not possible when the module is in the USB KB interface The module should not be in use by any application Performing an update to the scan module should only be done when the module is not actively bei...

Page 24: ...Software Features 16 DSE0420 NOTES ...

Page 25: ...dB octave 80 to 350 Hz 0 4 G2 Hz 350 Hz to 2 kHz Ramp down at 0 04 G2 Hz at 3 dB octave 2 Environmental Storage Temperature 40 C to 70 C Operating Temperature 15 C to 55 C Humidity non condensing 95 4 ESD The Scan Engine must be shielded from ESD strikes up to 15KV with the enclosure To date testing on the Imager Module has been performed at level of 2 5KV on the connector The module was tested in...

Page 26: ...Quality and Reliability 18 DSE0420 NOTES ...

Page 27: ... maximum lamp duration 15ms repetition rate 16 6 ms Lamp Standard IEC 62471 Exempt Radiated Emissions EN 55022 2010 Support Documentation Support documentation is available on request to assist the ODM in their sys tem submittal to Regulatory and Safety Agencies Some examples of support documentation are Laser Safety Classification Calculation Lamp Standard Calculation RoHS documentation ...

Page 28: ...Regulatory Safety 20 DSE0420 NOTES ...

Page 29: ...II Case L1 Environmental Conditions GM Ground Mobile Maximum Ambient Temperature 55 oC Internal Temperature rise 7 oC DSE0420 MTBF Duty Cycle Operating Temperature 25ºC Operating Temperature 55ºC 100 218 412 hrs 60 125 hrs 50 399 416 hrs 109 785 hrs DSE0420 RAMM Duty Cycle Operating Temperature 25ºC Operating Temperature 55ºC 100 0 00334 0 01214 50 0 00183 0 00665 ...

Page 30: ...T DEMONSTRATED LIFE TEST RESULTS AND ACTUAL FIELD DATA Any requests for reliability information on our products are granted with a clear understanding that MTBF RAMM numbers are design targets They are based on all available reliability data from preceding product demonstrated life testing and calculated semiconductor failure rates They do not repre sent an implied warranty As with all reliability...

Page 31: ...pendix B Mechanical Drawings This section describes the main mechanical features related to the following key points Overall Dimensions Optical features Exit Window Positioning Interface Connector Characteristics Requirements ...

Page 32: ...24 DSE0420 Overall Dimensions ...

Page 33: ...Integration Guide 25 Optical features ...

Page 34: ...26 DSE0420 Exit Window Positioning For additional information about the Scan Engine please refer to the DE2011 DL Integration Guide ...

Page 35: ...Integration Guide 27 Interface Connector Characteristics Requirements ...

Page 36: ...28 DSE0420 NOTES ...

Page 37: ......

Page 38: ... Telephone 1 541 683 5700 Fax 1 541 345 7140 2014 Datalogic Inc All rights reserved Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U www datalogic com 820063614 Rev B July 2014 ...

Reviews: