READING FEATURES
95
9
Auto PackTrack Report
The Auto PackTrack Report file can be downloaded from the Master scanner RAM by using
the
Tools>File transfer…
menu in Genius™. The report is divided into three sections.
The first section contains the general calibration parameters:
--------------------------------------
PARAMETERS
--------------------------------------
Calibration type
XYZ X Absolute (X Offset 550)
Sensor type
configured
Pack version
2 (Z Offset 0)
The second section contains for each node, the calibration table, and the final calibration
state.
--------------------------------------
PACKTRACK GLOBAL CALIBRATION TABLE DX node 5
--------------------------------------
P1: X(mm)
36
P1: Y(mm)
1077
P1: Z(mm)
10
P1: Distance(mm)
36
P1: Position
1077
P2: X(mm)
715
P2: Y(mm)
1096
P2: Z(mm)
10
P2: Distance(mm)
10
P2: Position
715
P3: X(mm)
518
P3: Y(mm)
1304
P3: Z(mm)
650
P3: Distance(mm)
1096
P3: Position
10
XP1: X(mm)
36
XP1: Y(mm)
1077
XP1: Z(mm)
10
XP1: Distance(mm)
36
XP1: Position
1077
XP2: X(mm)
715
XP2: Y(mm)
1096
XP2: Z(mm)
10
XP2: Distance(mm)
10
XP2: Position
715
XP3: X(mm)
518
XP3: Y(mm)
1304
XP3: Z(mm)
650
XP3: Distance(mm)
1096
XP3: Position
10
Calibration State
VERIFIED
--------------------------------------
PACKTRACK CALIBRATION TABLE DS node 6
--------------------------------------
P1: X(mm)
36
P1: Y(mm)
1077
P1: Z(mm)
10
P1: Distance(mm)
36
P1: Position
1077
P2: X(mm)
715
P2: Y(mm)
1096
P2: Z(mm)
10
P2: Distance(mm)
10
P2: Position
715
P3: X(mm)
518
P3: Y(mm)
1304
P3: Z(mm)
650
P3: Distance(mm)
1096
P3: Position
10
Calibration State
VERIFIED