READING FEATURES
87
9
The decoder will be able to read the label with a tilt angle b max and - max as
shown in the following figure:
Conveyor
Laser Beam
No Read
No Read
-
+
0
°
OK
OK
OK
OK
OK
No Read
Figure 104
– Reading Zones with Max
9.3
PACKTRACK™
PackTrack™ is a patented operating mode for Datalogic Omni-Directional Reading Stations
used to correctly assign codes read on different packs when placed in the scanner Reading
Area at the same time.
In fact, in the following example, the codes of two or more consecutive packs are found at
the same time in the scanner reading area. Therefore, the condition occurs where, in the
sequence of the two packs, the code of the second pack is read first, just before the code of
the previous pack. A system without PackTrack™ would assign the code of the second pack
to first pack and vice versa, thus causing a gross error in sortation.
Figure 105
– PackTrack™ System Layout
Working in
PackTrack™ mode requires an encoder and a presence sensor (or equivalent
signals) to track the moving packs.