DP1200
22
2
8/10
+
9/11
-
USER INTERFACE
DP1200
VS
1, 3, 6
2, 4, 7
GND
V
Signal
+ 5V
Figure 21 - Input PNP command using DP1200 power
The electrical features of the inputs are:
Maximum voltage = 30 Vdc
Maximum current = 25 mA.
An anti-disturbance hardware filter is implemented on the External Trigger input
(about 1 millisecond delay).
An additional 15 ms (typical) delay can be implemented through a dedicated software
parameter (refer to WinHost Help On Line).