11.
Digital I/O Setting
Digital Output Lines Setting
Output 6
Use = Redundancy
.
NOTE
Only one Controller (the Working or the Protecting) will have the OUT-6
On. This output is used to inform the Host about which is the Active
Controller:
OUT-6 On = Controller is Active
OUT-6 Off = Controller is in Stand By
12.
Operating Modes
Minimum Distance Between Packs (mm) = 200
.
13.
Operating Modes
Minimum Pack Length (mm) = 200
.
14.
Operating Modes
Window Dimension (mm) = 200
.
NOTE
This three parameters above are very important in order to avoid
Glitch and packs too short or too near not realistic as you can see in
the picture below.
200 mm
Glitch or pack too short
15. Send the configuration to the
Working
Controller: Send with O Environmental
Parameters.
16. Save the configuration on the PC.
2.7.2 Master Protecting Controller REDS configuration
Starting from the Default, complete the
Protecting
Controller configuration as follow:
1. Load the Configuration of the
Working
Controller from the PC.
2. Change only the parameter:
Redundancy Parameters
Topology Redundancy =
Master Protecting
.
3. Send the configuration to the
Protecting
Controller: Send with O Environmental
Parameters.