background image

C-BOX 200

Installation Manual

Summary of Contents for C-BOX 200

Page 1: ...C BOX 200 Installation Manual...

Page 2: ...C BOX 200 INSTALLATION MANUAL...

Page 3: ...tibilit lectromagn tique et la s curit des produits ber die Ann herung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Vertr glichkeit und Produktsicherheit entsprechen Basado en la a...

Page 4: ...cal Connections and Setup 6 2 4 1 Power Supply 7 2 4 2 System Wiring 8 2 4 3 Chassis Grounding Jumper Settings 10 2 4 4 Multidrop Address Selection 11 2 4 5 RS485 Bus Termination 12 2 4 6 Connection t...

Page 5: ...he section Safety Precautions at the beginning of this manual 2 Correctly position and mount the C BOX 200 within the reach of the barcode scanner cable according to the information in paragraph 2 3 3...

Page 6: ...v C BOX 200 General View 1 2 3 Figure A 25 pin scanner connector Cover screws 4 Compression connectors 1 2 3...

Page 7: ...e B Power switch ON OFF 1 2 Spring clamp terminal blocks 3 Multidrop address switches 5 4 Power on LED Warning LED 6 Tx LED 7 GET button 8 9 10 SEND button Auxiliary port connector Chassis grounding s...

Page 8: ...ORMATION BEFORE INSTALLING THE PRODUCT This product is intended to be installed by Qualified Personnel only The C BOX 200 is intended to be supplied by an NEC Class 2 power source rated 10 30 V minimu...

Page 9: ...viii...

Page 10: ...used over long distances or in electrically noisy environments Get the scanner configuration and store it in memory Send the configuration stored in memory to the scanner The C BOX 200 mechanical dim...

Page 11: ...N 2 1 PACKAGE CONTENTS Verify that the C BOX 200 and all the parts supplied with the equipment are present and intact when opening the packaging the list of parts includes 1 C BOX 200 2 Installation m...

Page 12: ...ng the four cover screws WARNING The C BOX 200 must be disconnected from the power supply during this operation Figure 2 2 Opening the C BOX 200 It is possible to perform the following operations Proc...

Page 13: ...C BOX 200 DATALOGIC 4 Installation 2 3 MECHANICAL INSTALLATION The diagram below gives the overall dimensions of the C BOX 200 and may be used for its installation mm in Figure 2 3 Overall dimensions...

Page 14: ...ure Figure 2 4 To mount the C BOX 200 1 Open the C BOX 200 by unscrewing the 4 cover screws If necessary using the two mounting holes inside the device as a pattern mark the panel with an appropriate...

Page 15: ...for more details The scanner auxiliary interface signals are also available on the internal spring clamp connectors After making system cabling and switch settings see sub paragraphs under 2 4 connect...

Page 16: ...OFF for both the C BOX 200 and the connected scanner ON OFF S1 Figure 2 6 Power switch ON OFF positions C BOX 1 2 VS GND USER INTERFACE GND V 10 30 Vdc Figure 2 7 Power supply connections NOTE Pin 1 i...

Page 17: ...the C BOX 200 housing 4 To connect the power and input output signals Prepare the individual wires of the system cables by stripping the insulation back approximately 1 cm Using a device such as a sc...

Page 18: ...SGND DS2100 DS2400 DS4300 DS4600 22 OUT REF OUT1 24 OUT REF OUT2 25 26 NC Reserved 29 NC IN1 30 NC IN1 31 NC IN2 32 NC IN2 36 RTSA GND 38 CTSA SGND AUX The signals on pins 9 10 11 and 12 are repeated...

Page 19: ...chassis can be connected to earth ground only if pins 7 or 8 are connected to a good earth ground or to the power supply ground signal The scanner chassis can also be left floating but in this case th...

Page 20: ...ide the C BOX 200 The valid address range is from 00 to 31 This value is read only at power on any change at run time has no effect If an invalid value is detected 32 99 the C BOX cannot communicate w...

Page 21: ...Multiplexer applications the termination resistor must be enabled ONLY on the last device of the chain the farthest away from the Multiplexer assuming the Multiplexer is the first device of the chain...

Page 22: ...RTX485 9 10 11 12 RTX485 RTX485 9 10 11 12 CABLE SHIELD RS485 REF CABLE SHIELD RS485 REF RTX485 10 11 12 9 RTX485 16 15 14 13 16 15 14 13 CABLE SHIELD RS485 REF RTX485 RTX485 CABLE SHIELD RS485 REF R...

Page 23: ...g clamp terminals for applications which use the OM4000 Oscillating Mirror in Trigger Mode They are used together and they have the following significance when a jumper is in the J1 position see Figur...

Page 24: ...WinHost or for data monitoring The details of the connector pins are indicated in the following table Figure 2 14 9 pin male connector 9 pin connector pinout Pin Name Function 1 N C 2 RXA Auxiliary RS...

Page 25: ...the C BOX 200 gets its main interface speed from the scanner to initialize its RS485 Multidrop optocoupled serial interface If both the baud rate and the device address are correct the communication t...

Page 26: ...ght button corresponding to the SEND function GET left button the C BOX 200 reads the current scanner configuration and permanently copies it in its own memory support EEPROM The C BOX 200 preserves t...

Page 27: ...the C BOX 200 is connected to the power supply and the power switch is ON WARNING red indicates a warning or error condition it is ON when a connection procedure is in progress the system is busy or d...

Page 28: ...340 g 12 oz SOFTWARE FEATURES Parameter storage Non volatile internal memory ENVIRONMENTAL FEATURES Operating temperature 10 to 50 C 14 to 122 F Storage temperature 20 to 70 C 4 to 158 F Humidity max...

Reviews: