CBX ELECTRICAL CONNECTIONS
21
4
4.5 OUTPUTS
Three optocoupled general purpose outputs are available. The meaning of the outputs can be
defined by the user. They are typically used either to signal the data collection result or to control
an external lighting system.
The electrical features of the two outputs are the following:
V
CE
= 30 Vdc max.
I
CE
= 40 mA continuous max.; 130 mA pulsed max.
V
CE saturation
= 1 Vdc max. @ 10 mA
P
D
= 80 mW Max. @ 45 °C ambient temp.
The output signals are fully programmable. Refer to the Discrete Output tool section in the
Impact Reference Guide for further details.
OUTPUT CONNECTIONS USING CBX POWER
Note: The strobe signal connection is shared with Output 3. If a non-zero value is defined for the Strobe Pulse Length
value (in VPM – Impact – General), the strobe is active. If the value is zero, Output 3 is active.
CAUTION
Power is available directly to the Output Device, independently from the
Power Supply Switch inside the CBX.
Figure 22 - Open Emitter Output Using CBX Power
CBX500
Function
+V
Power Source - Outputs
O1+
Output 1 +
O1-
Output 1 -
O2+
Output 2 +
O2-
Output 2 -
O3A
/ Output 3 + (See Note)
O3B
Strobe - / Output 3 -
-V
Power Reference Outputs
Summary of Contents for A30
Page 1: ...A30 Hardware Guide Publication 843 0153 Rev B...
Page 10: ......
Page 20: ...A30 HARDWARE GUIDE 10 3 Figure 5 Mounting Bracket Overall Dimensions mm in...
Page 28: ...A30 HARDWARE GUIDE 18 4 Figure 17 NPN External Trigger Using External Power...
Page 30: ...A30 HARDWARE GUIDE 20 4 Figure 21 NPN Input 2 Using External Power...
Page 45: ...CAMERA ELECTRICAL CONNECTIONS 35 5 Figure 42 Open Collector Output Connection...
Page 55: ...SOFTWARE CONFIGURATION 45 8...
Page 64: ...www datalogic com...