A30™ HARDWARE GUIDE
4
1
STEP 3 – MOUNT AND POSITION THE CAMERA
1. Mounting solutions are provided in Chapter 0 of this Hardware Guide.
STEP 4 – FOCUS THE CAMERA
1. Remove the lens cover.
2. Attach the correct accessory lens for your application.
3. Replace the lens cover, if needed.
4. Power the camera on. On the connector side of the camera near the cable, the “POWER
ON” LED (blue) indicates the camera is correctly powered.
5. Start Impact Vision Program Manager (VPM) and use it to connect to the camera.
6. Direct the camera toward a correctly lighted calibration image or other clearly defined object.
7. Select the Settings tab, then click the Camera system object.
8. In the Camera Setup tab, click the Live button.
9. Adjust the lens until the image is clearly in focus in the VPM image window.
STEP 5 – CALIBRATE IMAGE DENSITY
In order to function correctly when inspecting images, the camera needs the image resolution or
PPI (pixels per inch). This calibration procedure is necessary for first time installation, if the lens
type is changed, or if the focal distance is changed.
There are several methods available for calibrating the camera. Refer to the Calibration Panel
section of the Impact Reference Guide (Publication # 843-0093) for complete details.
Summary of Contents for A30
Page 1: ...A30 Hardware Guide Publication 843 0153 Rev B...
Page 10: ......
Page 20: ...A30 HARDWARE GUIDE 10 3 Figure 5 Mounting Bracket Overall Dimensions mm in...
Page 28: ...A30 HARDWARE GUIDE 18 4 Figure 17 NPN External Trigger Using External Power...
Page 30: ...A30 HARDWARE GUIDE 20 4 Figure 21 NPN Input 2 Using External Power...
Page 45: ...CAMERA ELECTRICAL CONNECTIONS 35 5 Figure 42 Open Collector Output Connection...
Page 55: ...SOFTWARE CONFIGURATION 45 8...
Page 64: ...www datalogic com...