DC Supply Range:
9.0 - 16.0 V-DC.
DC supply current:
250 mA-DC typical @12V-DC
500 mA-DC max. @12V-DC
Alternator Voltage:
0-250 V-AC (Phase-Neutral)
Alternator Frequency:
0-100 Hz.
Mains Voltage:
0-250 V-AC (Phase-Neutral)
Mains Frequency:
0-100 Hz.
Load Current:
3x25A / 230V-AC continuous
Cranking Dropouts:
survives 0V for 100ms.
Fuel and Crank Relay Outputs:
40 A / 12V-DC
Auxiliary Output:
10A / 12 V-DC
Charge Excitation:
min 2 W.
Battery Charge Current:
min 1A / 13.7V-DC (195-250V-AC)
Operating temp.:
-
40°C (-40°F) to 70°C (158°F).
Storage temp.:
-
55°C (-67°F) to 80°C (176°F).
Maximum humidity:
95% non-condensing.
Dimensions:
200x 148 x 72 mm (GxYxD)
Panel Cutout:
176 x 121mm minimum.
Weight:
700 g (approx..)
Enclosure:
Flame retardant, high temp ABS/PC (UL94-V0)
IP Protection:
IP54 (front).
EU Directives
-2006/95/EC (low voltage)
-2004/108/EC (electromagnetic compatibility)
Reference standards for EU Conformity:
-EN 61010 (safety)
-EN 61326 (EMC)
6. TECHNICAL SPECIFICATIONS