CHAPTER 11. IPSAN CONFIGURATION
Keyword
Can be given for
Description
any
<uvid>, <uprio>, <svid>
and <sprio>
Any possible value will be
considered valid for this rule
cpy-user-cvlan
<vid>
The customer VLAN ID will
be copied from the incoming
tag
cpy-user-svlan
<vid>
The service VLAN ID will be
copied from the incoming tag
cpy-user-cprio
<prio>
The customer VLAN priority
will be copied from the in-
coming tag
cpy-user-sprio
<prio>
The service VLAN priority
will be copied from the in-
coming tag
11.7.3 Setting the VLAN TPID
When setting up a VLAN network all packets that are tagged will leave the GPON
network with the standard TPID 0x8100. It is possible to change this value to
one of 4 available values for each unit as a whole. This can be achieved with the
following single command in the configuration menu.
unit <unit> gpon vlan-tpid <tpid>
Description of the used parameters:
Name
Format
Description
<unit>
Number (1-7)
Unit the rule should be applied to
<tpid>
0x8100, 0x88a8, 0x9100 or 0x9200
VLAN TPID that should be used
Note:
When using double-tagged frames this rule only applies for the outer tag.
Changing the inner tag’s TPID is currently not possible at the IPSAN. Example:
DM4650(config)#unit 7 gpon vlan-tpid 0x88a8
DM4650(config)#
11.8 Additional ONU Configuration
For the configuration of an ONU it is assumed that the ONU is already registered
at the IPSAN. The following steps are done in the configuration menu. To
configure the ONU it is necessary to go into the ONU menu by typing: