background image

Summary of Contents for SS series SPAN

Page 1: ...Reserved June 2007 541 0106 U A 01 SPAN and Multi link Aggregators Regenerators USERguide SS series SPAN Aggregators Regenerators VS series SPAN Aggregators Regenerators VS series Multi link Aggregators Regenerators SS series SPAN VS series SPAN VS series Multi Link ...

Page 2: ......

Page 3: ...o the technology described herein If applicable you may return the product to the place of purchase for a full refund Trademark Attribution DS3 ACTIVEtap DS3switch Empowering Network Professionals ETHERNETtap FDDIswitch FIBERsplitter FIBERswitch FIBERSWITCH system GIGABITswitch INSERTswitch INSERTunit LANswitch MULTINETswitch NETspan PERMAlink PROline RMON SWITCHING analyzer SINGLEstream UNIVERSAL...

Page 4: ...000 3 3 This equipment has completed the Product Safety Review and found to meet the Low Voltage Directive 72 23 EEC 1993 requirements NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a com...

Page 5: ...eam SPAN Series Hardware Description 17 Application Hardware Installation 21 Dual Homed Server Application 21 Full Duplex aggregated Application 22 Primary Redundant Router Application 23 VERSAstream Multi link Series Aggregators Regenerators Overview 25 VERSAstream Multi link Series Features Benefits 26 VERSAstream Multi link Series Specifications 27 VERSAstream Multi link Series Hardware Descrip...

Page 6: ...1 USERguide VS series SPAN Aggregators Regenerators 1 VS 1022BT BT 1062BT 1031BT 1031BT 02 1082 1082LX BT 1082SX BT 1082SX SX 1041SX SX or 1022SX SX 2 Switching AC Adapters 2 AC Power Cords 1 Warranty Card 1 QUICKinstall Guide 1 USERguide VS series Multi link Aggregators Regenerators 1 VS 1026BT BT 1028 1028SX 1046 1046SX 1412 kit or 1610 kit 2 Switching AC Adapters 2 AC Power Cords 1 Warranty Car...

Page 7: ...fore sending it to the connected monitoring and analysis devices expanding network visibility and reducing the number of tools needed on the network Fewer tools means lower equipment and licensing costs And because the SPAN and Multi link Aggregator Regenerators aggregates all the data before sending it to the connected network device you can always view the entire conversation even in asymmetric ...

Page 8: ...ent needs to be monitored Multipoint analysis enables you to seamlessly analyze a packet at multiple points in your network with one tool know exactly what is happening to data as it moves through your network View all the data from multiple network segments allows you to monitor and ana lyze traffic from asymmetric routing paths load balanced applications and redun dant environments Two monitor p...

Page 9: ...s SPAN Aggregator Regenerator redundant power supply design has been thoroughly tested Even if power is lost to the tap network traffic will continue to flow uninter rupted SS 200 Features Benefits Simple plug and play solution requires no additional configuration of external monitoring devices Connect any protocol analyzers probes intrusion detection systems and such for permanent In Line mon ito...

Page 10: ...nts Two external power supplies 5 VDC 1 A Operating Temperature 0O to 40O C 32O to 104O F Storage Temperature 30O to 65O C 22O to 149O F Humidity Less than 95O C non condensing Dimensions 1 10 H x 5 75 W x 5 75 D includes RMC 3 panel bracket 28 mm H x 146 mm W x 146 mm D Weight Unit 12 ounces Shipping 2 pounds SINGLEstream SS 201 SS 202 SS 203 SS 200 TCP Reset 2 10 100BT 2 10 100BT NO 2 100BT 2 10...

Page 11: ...en established between the NETWORK A connector and NETWORK A device The NETWORK B LINK LED illuminates indicating link has been established between the NETWORK B connector and NETWORK B device The TAP 1 LINK LED illumi nates indicating link has been established between the TAP 1 connector and monitoring device NIC net work interface card The TAP 2 LINK LED illuminates indicating link has been esta...

Page 12: ...nect both power supply barrel connectors into the POWER 1 and 2 ports respec tively of the SINGLEstream SS 100 Plug the power Supplies into the external power source furthermore connecting the second power supply to a different external power source circuit than the first power supply eliminates power as a single point of failure The POWER 1 and 2 LEDs illuminate indicating power 1 and 2 respectiv...

Page 13: ... B device The network is bidirectional Tx Rx path sensitive and correct connection is indicated by simultaneously illuminated NETWORK A and NETWORK B LINK LEDs When con necting the second network device causes the first LINK LED to go out and both LINK LEDs are NOT illuminated the network connection is backwards Reverse NETWORK A and NETWORK B connections and link will be established The NETWORK A...

Page 14: ...It s that simple No other configuration is nec essary Asymmetric routing EtherChannel and load balanced environments use multiple paths to send data reassembling it as the data reaches its destination The VERSAstream SPAN aggregator regenerator makes monitoring and analyzing mul tiple data paths less of a challenge for network managers The VERSAstream SPAN aggregator regenerator aggregates the two...

Page 15: ...ial costs and recurring licensing fees maximize your ROI by deploying fewer network taps and monitoring devices Operates at 10 Mbps 100Mbps or 1000 Mbps and supports full duplex and half duplex auto negotiation Redundant power supply insures seamless monitoring even if the main power source is unavailable to the tap A simple plug and play solution requiring no additional configuration or configu r...

Page 16: ...nitor 10 100 1000 BaseT Ethernet 1000SX or 1000LX 10 100 1000 BaseT Ethernet and or 1000SX Feature Cable Type Network Monitor CAT 5E BT 50 or 60 5 micron SX or 9 micron LX CAT 5E BT and or 50 or 60 5 micron SX Port Connectivity NETWORK MONITOR RJ45 or Duplex LC RJ45 and or Duplex LC Power Two external power supplies 120 240 VAC 80 W Operating Temperature 0O to 40O C 32O to 104O F Storage Temperatu...

Page 17: ...re 12 illustrates the VERSAstream SPAN Series aggregator regenerator front panel This is the location for all cable connections and status LEDs Figure 3 VS 1022BT BT Front Panel and functional diagram Figure 4 VS 1022SX SX Front Panel and functional diagram Figure 5 VS 1031BT and VS 1031BT 02 TCP reset Front Panel and functional diagram ...

Page 18: ...AN and Multi Link Aggregators Regenerators USERguide 18 Figure 6 VS 1041LX LX Front Panel and functional diagram Figure 7 VS 1041SX SX Front Panel and functional diagram Figure 8 VS 1062BT Front Panel and functional diagram ...

Page 19: ...AN and Multi Link Aggregators Regenerators USERguide 19 Figure 9 VS 1082 Front Panel and functional diagram Figure 10 VS 1082LX BT Front Panel and functional diagram Figure 11 VS 1082SX BT Front Panel and functional diagram ...

Page 20: ...vely are on Either LED not illuminated indicates a defective power source and immediate replacement is required to insure redundant power integrity NETWORK These ports are either RJ45 or duplex LC connectors used for connection to SPAN network connections The LED Display Code table deciphers the RJ45 jacks with integrated LEDs that display line status and line speed of each port The LED associated...

Page 21: ...e Dual Homed Server Distribution Network This VS 1022SX SX is similiar to other VERSAstream SPAN series installations To connect the VERSAstream VS 1022SX SX SPAN Series aggregator regenerator refer to Figure 13 and follow these steps 1 Two power supplies are provided Use of the second power supply is strongly recommended to assure uninterrupted monitoring Connect both power supply barrel connecto...

Page 22: ...g green when data is passed from the respective moni tor port to the analysis device Full Duplex aggregated Application shown in Figure 14 focuses on monitoring and analyzis of the full duplex aggregated input into one single stream of data using a FIBERtap in conjunction with the VS 1022SX SX This VS 1022SX SX is similiar to other VERSAstream SPAN series installations To connect the VERSAstream V...

Page 23: ...eplacement is required to insure redundant power integrity 2 Connect one network device duplex SC plug to the FIBERtap duplex SC B OUT and A IN connector 3 Connect the other network device duplex SC plug to the FIBERtap duplex SC A OUT and B IN connector 4 Using either a DRL490 2m 62 5 micron for SX Cable or a DRL491 2m 9 micron for LX Cable connect the FIBERtap duplex SC A OUT and B OUT connector...

Page 24: ...ower 1 and 2 respectively are on Either LED not illuminated indicates a defective power source and immediate replacement is required to insure redundant power integrity 2 Connect network cables to the VERSAstream RJ45 NETWORK ports The NETWORK RJ45 left integrated LED is solid green indicating link has been established on the port The LED Display Code table deciphers the RJ45 jacks with integrated...

Page 25: ...le network seg ments and aggregates all the data before sending it to the connected monitoring and analysis devices expanding network visibility and reducing the number of tools needed on the network Fewer tools means lower equipment and licensing costs And because the VERSAstream aggregates all the data before sending it to the connected network device you can always view the entire conversation ...

Page 26: ...s load balanced applications and redun dant environments Two monitor ports 4 port model available allow two Gigabit Gbps devices to simultaneously monitor the same links providing extended security and analysis options while eliminating contention for network access Simple plug and play solution requires no additional configuration or configuration of external monitoring devices Save money on recu...

Page 27: ...1000SX LC 2 1000SX LC 6 10 100 1000 2 1000SX LC 2 10 100 1000 NETWORK PORT SPEED Mb MONITOR PORT SPEED Mb Optional Rack Mount RMC 2 RMC 2 RMC 2 RMC 2 VS 1610 kit 10 10 100 1000 4 1000SX LC 2 10 100 1000 RMC 2 VS 1028 VS 1046SX 6 1000SX LC 4 1000SX LC 8 10 100 1000 2 1000SX LC RMC 2 RMC 2 Specification Channel Network Monitor 10 100 1000 BaseT Ethernet or 1000SX 10 100 1000 BaseT Ethernet and or 10...

Page 28: ...16 through Figure 22 illustrates the VERSAstream Multi link Series aggregator regenerator front panel This is the location for all cable connections and status LEDs Figure 16 VS 1026BT BT Front Panel and functional diagram Figure 17 VS 1028 Front Panel and functional diagram Figure 18 VS 10282SX Front Panel and functional diagram ...

Page 29: ...and Multi Link Aggregators Regenerators USERguide 29 Figure 19 VS 1046 Front Panel and functional diagram Figure 20 VS 1046SX Front Panel and functional diagram Figure 21 VS 1412 Front Panel 1 of 2 in kit and functional diagram ...

Page 30: ...grity NETWORK These ports are either RJ45 or duplex LC connectors used for connection to SPAN network connections The LED Display Code table deciphers the RJ45 jacks with integrated LEDs that display line status and line speed of each port The LED associated with each duplex LC jack indicates when light signal has been detected on the respective Rx NETWORK port 1 000 Mbs 100 Mbs 10 Mbs Green Orang...

Page 31: ...lerance Common Gigabit EtherChannel configurations combine up to eight Gigabit Ethernet segments into a single logical channel between switches routers and servers For example a four link Gigabit EtherChannel takes four Gigabit full duplex links a total bandwidth 2000 MB and combines them into one virtual link a total bandwidth of 8000 MB effectively quadrupling bandwidth These links are managed a...

Page 32: ...rnet network segments into one stream of data A single Gigabit device such as an intru sion detection system protocol analyzer or network probe can receive the aggregated data with just one network interface card NIC It requires no software no configuration and no admin istration Application Hardware Installation Figure 23 through Figure 25 depict typical application installations of VERSAstream M...

Page 33: ...the respective NETWORK port and network device The LED Display Code table deciphers the RJ45 jacks with integrated LEDs that display line status and line speed of each port The LED is flashing green when data is passed from the respective network device to the network port 1 000 Mbs 100 Mbs 10 Mbs Green Orange OFF LED Display Code Link Data Code Left LED Solid Green Flashing Green Code WITH LINK O...

Page 34: ... VERSAstream VS 1028 Multi Link Aggregator application deployed with Datacom Taps to combine traffic from different network segments and output the aggregated data to either a single network tool or two connected monitoring devices This VS 1028 is similiar to other VERSAstream Multi link series installations Figure 24 VS 1028 with Taps Application ...

Page 35: ...ect network cables to the VERSAstream NETWORK RJ45 ports The NETWORK RJ45 Link LED is solid green indicating link has been established between the respective NETWORK port and network device The LED Display Code table deciphers the RJ45 jacks with integrated LEDs that display line status and line speed of each port The LED is flashing green when data is passed from the respective network device to ...

Page 36: ... gain complete visibility into your SPAN and In Line environments combining traffic from up to 8 different segments and outputting the aggregated data to two connected monitoring devices Monitoring or analyze with multi segment aggrega tion means less deployment and maintenance costs This VS 1028 is similiar to other VERSAstream Multi link series installations Figure 25 VS 1028 SPAN and In Line Ap...

Page 37: ...the respective NETWORK port and network device The LED Display Code table deciphers the RJ45 jacks with integrated LEDs that display line status and line speed of each port The LED is flashing green when data is passed from the respective network device to the network port 3 Connect analysis devices to the VERSAstream MONITOR ports Two DRL494 2m cables are provided to connect analysis SC ports to ...

Page 38: ...igure 26 focuses on a typical VERSAstream VS1610 kit Two VS 1610s mounted in RMC 2 Rack Mount Chassis and daisy chained together Multi Link Aggregator deployed This VS 1610 kit is similiar to the VS 1412 kit VERSAstream Multi link series installation Figure 26 VS1610 kit Typical Application and functional diagram ...

Page 39: ... the respective NETWORK port and network device The LED Display Code table deci phers the RJ45 jacks with integrated LEDs that display line status and line speed of each port The LED is flashing green when data is passed from the respective network device to the network port 3 Connect analysis devices to the VERSAstream MONITOR ports Two DRL494 2m cables are provided to connect analysis SC ports t...

Page 40: ...Datacom Systems Inc SPAN and Multi Link Aggregators Regenerators USERguide 40 ...

Page 41: ...SI during the Warranty Period and DSI will repair or replace the defective equipment and return it to you freight pre paid If DSI determines that the equipment is not defective it will return it to you freight collect DSI shall have no responsibility for any deficiency resulting from accidents misuse modifications power disturbances including use of a power supply not specified by DSI or various o...

Page 42: ...Datacom Systems Inc SPAN and Multi Link Aggregators Regenerators USERguide ...

Page 43: ......

Page 44: ...Datacom Systems Inc 2004 by Datacom Systems Inc All Rights Reserved www datacomsystems com ...

Reviews: