Step 3.
Connect the other primary network cables to the primary SINGLE
stream
™
S-100 RJ45 port
NETWORK B
connector. The
NETWORK-B LINK
LED illuminates indicating link has been
established between the NETWORK B connector and primary NETWORK B device.
!!!:
The network is bidirectional Tx/Rx path sensitive and correct connection is indicated by
simultaneously illuminated
NETWORK-A
and
NETWORK-B
“
LINK
”
LEDs
.
W
hen con-
necting the second network device causes the first
LINK LED
to go out and both
LINK
LED
s are
NOT
illuminated, the network connection is backwards. Reverse NETWORK A
and NETWORK B connections and link will be established.
The
NETWORK-A
and
NETWORK-B ACT LEDs
illuminate as data is passed between the
primary NETWORK A and NETWORK B devices.
Step 4.
Connect the redundant network cables to the redundant SS-100 RJ45 port
NETWORK A
connector. The
NETWORK-A LINK
LED illuminates indicating link has been established
between the NETWORK A connector and redundant NETWORK A device.
NOTE: Let the “LINK” LED be your guide.
If you are properly connected,
NETWORK-A
and
NETWORK-B
“
LINK
”
LEDs
remain illuminated simultaneously.
Step 5.
Connect the other redundant network cables to the redundant SS-100 RJ45 port
NET-
WORK B
connector. The
NETWORK-B LINK
LED illuminates indicating link has been
established between the NETWORK B connector and redundant NETWORK B device.
!!!:
The network is bidirectional Tx/Rx path sensitive and correct connection is indicated by
simultaneously illuminated
NETWORK-A
and
NETWORK-B
“
LINK
”
LEDs
.
W
hen con-
necting the second network device causes the first
LINK LED
to go out and both
LINK
LED
s are
NOT
illuminated, the network connection is backwards. Reverse NETWORK A
and NETWORK B connections and link will be established.
The
NETWORK-A
and
NETWORK-B ACT LEDs
illuminate as data is passed between the
redundant NETWORK A and NETWORK B devices.
Step 6.
Connect the primary
TAP 1
port connector into the SS-200 RJ45 port
NETWORK B
con-
nector. The
NETWORK-B LINK
LED illuminates indicating link has been established
between the NETWORK B connector and the primary SINGLE
stream
™
SS-100 .
Step 7.
Connect the redundant
TAP 1
port connector into the SS-200 RJ45 port
NETWORK A
connector. The
NETWORK-A LINK
LED illuminates indicating link has been established
between the NETWORK A connector and the redundant SINGLE
stream
™
SS-100 .
Step 8.
Connect one SS-200 tap cable from the
TAP 1
port connector into the IDS monitoring
NIC. The
TAP 1 LINK
LED illuminates indicating link has been established between the
SINGLE
stream
™
SS-200 TAP 1 connector and IDS monitoring NIC. The
SINGLE
stream
™
SS-200
TAP 1 ACT
LED illuminates as data is passed to the TAP 1 IDS
.Step 9.
Connect the other SS-200 tap cable from the
TAP 2
port connector into the analyzer
monitoring NIC. The
TAP 2 LINK
LED illuminates indicating link has been established
between the TAP 2 connector and analyzer monitoring NIC. The SINGLE
stream
™
SS-
200
TAP 2 ACT
LED illuminates as data is passed to the TAP 2 analyzer.
Summary of Contents for SS series SPAN
Page 2: ......
Page 40: ...Datacom Systems Inc SPAN and Multi Link Aggregators Regenerators USERguide 40 ...
Page 42: ...Datacom Systems Inc SPAN and Multi Link Aggregators Regenerators USERguide ...
Page 43: ......
Page 44: ...Datacom Systems Inc 2004 by Datacom Systems Inc All Rights Reserved www datacomsystems com ...