EASY
SENSE Q3+ and Q5+
DO185 (2)
used in an investigation e.g. the distance from A to B or the length of the interrupt
card.
For example:
Line 1 – What is
being calculated
Line 2 – Interrupter used Line 3 – Measurements required
Speed at A
1 Interrupt card
Length of card (mm)
2 Interrupt card
█▄█
Length of segment (mm)
Speed from A to B
Distance from A to B
Distance between A and B (m)
Accel. at A
2 Interrupt card
█▄█
Length of segment (mm)
Accel from A to B
Distance from A to B
Distance between A and B (m)
Timing options
Time at A
Timing starts when the signal at input A changes and
stops when the signal reverts back.
•
With Light Gates it will be the time it takes for an object
to pass through the light beam.
•
For a Push Switch it will be the length of time that the
switch is kept depressed.
•
For Timing mats it will be the length of time someone
stands on the mat.
Time from A to B
Timing will start when a signal change is
detected at sensor A and stops when the
signal at B changes (so it measures the
time taken by an object to travel from
sensor A to sensor B).
The reading number of
this measurement
►
Time at A
Time at A
= 0.00000 s #0
t=0.000000 s n=0
The measurement
The average
measurement
Over this number
of
readings
Time from A to B
=0.00000 s #0
A
Start - A On
Stop - B On
B
t=0.000000 s n=0
►
Time from A to B
©
Data Harvest Group Ltd.
15