![Data Harvest EASYSENSE Q3+ User Manual Download Page 10](http://html.mh-extra.com/html/data-harvest/easysense-q3/easysense-q3_user-manual_511166010.webp)
EASY
SENSE Q3+ and Q5+
DO185 (2)
Meter
In this mode
EASY
SENSE Q will display measurements from the active sensors (built-in
and any plug-in sensors) on the LCD screen but will not store any data.
Use the green button t
check or change the
sensor range
o
Use the red button to pause
the screen (
▌▌
)
Use the blue buttons to
scroll through the sensors
•
Connect any plug-in sensors if required. If the display is turned off, press any button
to wake up
EASY
SENSE Q
.
System
•
Use the blue buttons (
▲▼
) to scroll the list until the
pointer is pointing at
Meter
.
►
Meter
Snapshot
Easy Log
•
Press the green button
►
to select
Meter
.
•
The blue buttons (
▲▼
) can be used to scroll and view data from the sensors.
•
The green button
►
can be used to check or change the sensors range (see below).
•
The red button
can be used to temporarily halt the updates to the sensors
readings. Two lines
▌▌
on the top left will indicate that the display is paused.
•
Press the green button
►
to cancel pause.
•
Press the red button
to exit
Meter
mode and return to the main menu.
Set sensor range
Some built-in and plug in
Smart Q
sensors have multiple ranges. The range of a sensor
can be altered whilst in Meter mode.
•
Whilst in Meter mode use the blue buttons (
▲▼
) to
scroll the list until the pointer is pointing at the
appropriate sensor.
•
Press the green
►
button.
Note:
If a sensor only has one range then its name will be momentarily displayed.
►
3) 50.9 dBA
4) 150 lx
5) 28.5
˚
C
6) 103.5 kPa
System
►
Meter
Snapshot
Easy Log
►
4) 498 lx
5) 25.5
˚
C
Light:
Outdoor 100k lx
►
*Indoor 1000 lx
In/Out 10k lx
An asterisk * will indicate the current range selected.
Use the blue (
▲▼
) buttons to scroll the list until the
pointer is pointing at the required range.
•
Press the green
►
button to select the range and return to Meter mode.
Notes:
•
The plug-in Temperature sensor supplied in the Q3+ or Q5+ pack will use the same range as the built-
in Temperature sensor.
•
The built-in sensor range will not be applied to any
Smart Q
Temperature, Light or Pressure sensors
that are connected. They will continue to use the settings stored in the
Smart Q
sensor.
©
Data Harvest Group Ltd.