4.2.8 Fault status 

(Displayed for 5 seconds) 

 

Display                                                  Type of error   

                                                          Fault number : number of times                   

                                                                                        Fault status 

 

 

 

 

 

 

 

4.3 Operation method 

4.3.1 Check points prior to operation 

 

-. Check the wiring and installation status of the inverter. 
 
-.  Especially,  check  that  input  polarity  of  solar  module  has  been  connected  correctly  and  the  line  to  grid  has 

been connected correctly. 

 
-.  Direct  power  of  solar  panel  is  supplied  to  the  inverter  and  AC  power  status  is  checked,  then  the  inverter 

operates automatically after 300 seconds 
(If necessary, a DC circuit breaker can be installed outside the inverter) 

 

4.3.2 Automatic operation 

 

  The inverter is set to auto-operation mode as default setting when shipped from the factory. 

The inverter operates automatically when the voltage of the solar panel is over setting value after sunrise and the 
inverter stops automatically when voltage of the solar panel is under setting value after sunset. 
 
The inverter always monitors the grid power and it stops automatically in abnormal status. 

 

 

5. Function 

 

5.1 Descriptions   

5.1.1 Grid monitoring 

Whether the system voltage is normal or abnormal is determined by the difference from the normal voltage (Fault 

high voltage, Fault low voltage), and if this value is higher or lower than the specified value, it stops the inverter. 
If the frequency of system voltage is off the line frequency by line fault frequency, it stops the inverter’s operation.   

In order to start the generation at the normal system status, it operates with the system after the line transition time 

elapses. Frequency of used system voltage can be set in accordance with the frequency band.   

 

 

5.1.2 MPPT control and total power generation 

 

As  the  output  of  solar  panel  varies  on  surrounding  temperature,  humidity  and  solar  ray  intensity,  MPPT 
(Maximum Power Point Tracking) algorithm should be carried out smoothly. The method applied to this product 
does not show the fluctuation in current, and it stops the inverter when the solar cells  reach the PV stop voltage 
and the inverter cannot be operated anymore.   

[001]                                            E008     

                      Under Voltage 

 

Summary of Contents for DSP-123K5-OD

Page 1: ...DASS Tech Photovoltaic Grid Connected Inverter DSP 123K5 OD ver1 0 Operation and Installation Manual...

Page 2: ...place 9 3 3 Terminal connection diagram 10 3 4 Wiring 11 3 5 Cautions for mounting the inverter to the wall 14 4 Operation 15 4 1 Display 15 4 2 Basic mode 15 4 3 Operation method 17 5 Function 17 5 1...

Page 3: ...te when the cover is open It could cause electric shock as high voltage terminal or electric charging is exposed outside Do not adjust switch when your hands are wet It could cause electric shock Do n...

Page 4: ...ase check external conditions Do not pile up beyond the limited level or height Do not open the cover while transported Do not drop or damage with shock as this device is a precision one 2 Application...

Page 5: ...llowed by the guidelines in this manual Do not drop or add damage to the inverter as this device is a pr cised one Do Class 3 grounding work 200V class for the inverter Don t place other home applianc...

Page 6: ...t impair the body seriously use the inverter after understanding the application or installation manual enough in using the inverter 2 1 2 Appearance of the product 2 1 3 Confirmation of Products Afte...

Page 7: ...normal operation impossible or cause a serious declination in lifetime In the event of worst case the inverter may be damaged by fire and use this device in right manner in accordance with the content...

Page 8: ...maintain the maximum power point through MPPT 6 Easy Parallel Operation If the capacity of solar cells increases the inverter can be added and connected for extension of capacity without any additiona...

Page 9: ...e IP 65 Outdoor Equipment noise 50 dB or less External dimension W x L x H 305 380 135 5 mm Full weight 9 9kg External interface RS 485 Monitoring Device Option DSP WR5 DSP ZR5 Wire Wireless RS485 232...

Page 10: ...e temperature 10 50 3 Avoid hot and humid place Relative humidity should be less than 90 No dewfall 4 Install the inverter at the place with no direct sun shine 5 As the inverter is a high temperature...

Page 11: ...Solar cell power DC Solar input power Connected with of Solar cell power RS485 Communication terminal Connect to signal line of the monitoring system AC Grid power connection terminal Inverter output...

Page 12: ...use a case or sash screw as an earth terminal For earth wire use exclusive earth wire complying with the standard Connect the earth terminal to the spot adjacent to the inverter The earth cable must...

Page 13: ...g cable and terminal Terminal used when connecting cable and connector Nut to fix the connecter inside the inverter To easily classify Inside Connector and Outside Connector is to check the difference...

Page 14: ...d of connector and inverter Notice Connect only the same polarity shown above 2 AC Connector wiring Connector Terminal Connector Terminal Connector Terminal Turn the nut to be fixed Nut Connector Term...

Page 15: ...See the wiring diagram 3 3 3 5 Cautions for mounting the inverter to the wall Installation Remove press fit spanner for the inverter by using a tool like long nose plier Remove Wall BKT from the inver...

Page 16: ...es the operation status of the inverter Green light inverter generation is normal Red flickering Fault 4 2 Basic mode 2 lines 16 characters LCD When the inverter power is ON information on the LCD is...

Page 17: ...2 5 Daily today generated power Display Unit Today today s generated power Wh Present power generated 4 2 6 Daily previous day generated power Display Unit DAY 1 previous day s generated power Wh Pre...

Page 18: ...er always monitors the grid power and it stops automatically in abnormal status 5 Function 5 1 Descriptions 5 1 1 Grid monitoring Whether the system voltage is normal or abnormal is determined by the...

Page 19: ...tion deletes the fault records occurred in the past and sets to ready mode Controlling the inner keypad randomly shall cause malfunction of the inverter You should contact DASS tech 5 1 4 Fault 1 Faul...

Page 20: ...contact us E007 Grid Over voltage Over voltage Abnormal grid voltage Check grid status and contact your electricity authority Then if the problem isn t solved contact us E008 Grid Under voltage Under...

Page 21: ...the date time and indications on the fault If the product does not work normally check the follows for requesting customer service 1 Name of model 2 Serial number of the product 3 Purchased place 4 Pu...

Page 22: ...ure occurred under normal using condition within the warranty period your product can be tested and repaired for free Charged A S For following cases A S could be provided at a cost The product is out...

Page 23: ...ustomer service 82 1588 7468 Tel 82 43 218 5670 Fax 82 43 218 5671 Headquarters DASS Tech Co Ltd 109 Yangcheongsongdae gil Ochang eup Cheongwon gu Cheongju si Chungbuk Korea http www dasstech com Ver...

Reviews: