Type
Ⅰ
connector installation instructions
Step 1
Select appropriate cables
according to Table 4-2, Remove the
insulation layer of the AC output cable
using a wire stripper according to the figure
shown below:
A: 30~50mm B:6~8mm;
Figure 4-12
Step2
Disassemble the AC connector
according to the figure shown below: insert
the AC output cable (with its insulation
layer stripped according to step 1) through
the waterproof locking cable gland;
Figure 4-13
Step 3
Connect AC output cable as per the following requirements:
Connect the yellow-green wire to the hole labeled "PE", fasten the wire using an Allen
wrench;
Connect the brown wire to the hole labeled "L", fasten the wire using an Allen wrench;
Connect the blue wire to the hole labeled "N", fasten the wire using an Allen wrench;
Figure 4-14
L--Brown, N--Blue, PE--Yellow-green