1. General safety rules
DASPI guarantees the good function of the present device
only if all advises and safety indications on this manual will
be fully respected. Daspi is not responsible for damages
caused to persons or things due to the incorrect use of the
device. This control panel can control ONLY drives for
industrial doors. Use the device only in dry rooms. Cut off
main power supply before and during any operation you
will do on the control panel. Follow all local safety norms if
you are operating on the control panel. Keep control and
net connections separated.
Control panel MACH9
operates only with dead-man function and can be
integrated by the card SCHEDA LOGICA LIFTER.
Following functions can be set up: traffic light, courtesy
light, automatic shutting working time.
2. Main
component
S01-S02
Key to adjust the OPENING (S01) / key to
adjust the CLOSING (S02)
X1
Terminal to connect the main power supply
400Vac - 230Vac
X2
Terminal to connect motor, emergency stop,
chain release and thermal protection
X3
Terminal for commands and safety devices
X4
Terminal to select the power supply 400Vac or
230Vac
X5
Terminal for the limit switches
X7
Molex for the logic card "Scheda Logica"
X9
Terminal for the flashing light or traffic light /
courtesy light (working ONLY with logic card)
X10
Jumper to set OPENING-CLOSING in
semiautomatic function or dead-man function.
(working ONLY with logic card)
How to connect the motor with power supply
400 V / 3phase
F1
Fuse power supply protection
F2
Thermic safety switch for the drive
motor
K1
Safety for the OPENING
K2
Safety for the CLOSING
M
Motor drive (400 V / 50 Hz / 3phase
S3
OPENING safety limit switch (N.C.
contact)
S4
CLOSING safety limit switch (N.C.
contact)
S7
Switch to control the manual
emergency manoeuvre (N.C. contact)
T1
Transformer
X1
Terminal to connect the power supply
X2
Terminal for the drive motor
X4
Terminal to select the power supply