Important safety warnings

 

Before installing, using or maintaining the Lifter gear reducer for powered sectional doors, carefully read these 
instructions and ensure compliance with all safety warnings that are marked in this manual as below.  

 

This symbol stands for “Caution” and precedes a general warning meant to avoid damages to persons and properties. 
Please carefully read this SAFETY chapter and make yourself familiar with these warnings. Motorised apparatus for 
sectional doors is designed and tested in order to ensure maximum door safety. However, compliance to these 
instructions is a mandatory condition for effective safety to be actually in place.  

 

This sign precedes life-saving warnings. DANGER! Lack of compliance may cause serious damage to persons and 
properties.  

 

 

Perfect door balanced must be ensured.

 If not so, 

further safety measures must be taken, such as for 
example installation of an anti-fall device. Doors that 
are blocked or not shifting well must be repaired before 
installing a motorised apparatus on them. Doors, 
springs, wires, disks and guide-rails are subject to 
extreme stress, which can cause serious injuries.   

 

The force applied on the border of the door while 
closing should not exceed 150 N (15 Kg). If the 
power applied for closing the door exceeds to  150 
N (10 kg), an additional safety device is required 
(see use of safety applications). Release force 
applied to an obstructed door can never be 
modified.  

 

Do not try to fix, release, move or align the door by 
yourself. Please, contact the manufacturer 
authorised service.  

 

Excessive power can cause failure to the normal 
reverse travel or even damage the door.  

 

A special sign or board should be made available near 
the control board in order to remind all users of the 
applicable safety procedures. 

 

Always wear appropriate protective cloths during 
maintenance or installation of the door-opener, 
including protective goggles, back-belts and protective 
gloves. During installation or maintenance, wear snug-
fitting cloths and avoid jewellery, watches or clothes, 
which could get entangled into the machine. In case of 
works to be carried out on ladders or elevated 
platforms, related safety procedures must be enforced. 

 

Remove any locks that could obstruct or damage the 
door. In the case of active safety locks, it is possible to 
install a release-switch. 

 

Remove all ropes and chains connected to the 
door before installing the opener. DANGER 

hanging 

wires, ropes, chains etc… may get wrapped and cause 
serious injuries.   

 

Install the control panel, the main switch and all 
other control devices in a place near the door away 
from children reach but visible and easy to access. 
Children must not be allowed to press buttons or 
play with remote controls. Incorrect use of the 
door-opener may cause serious injuries.  

 

Installation and electric connection works must be 
performed in compliance to the applicable local rules 
and regulations. Electrical wires can be connected to 
one single network and duly grounded. 

AVOID 

PLACEMENT OF THE SYSTEM in moist or wet 
places.  

 

All works on the door-opener must be carried out by 
skilled staff only.  

 

Operate the door-opener strictly only after having 
inspected the entire dangerous area around the 
door and having made sure that there are no 
obstacles or parts infringing this area. Ensure that 
the opener is duly installed and effectively prevent 
passage through the door while it is operating. 
Children must not be allowed to play near the door. 

 

The installation of this apparatus is subject to the 
procedures set forth by the EN12453. 

 

This motorised apparatus must be operated and 
connected in compliance with the International 
Standards EN13241-1 for door closing systems 
and EN 60335-1 for home appliances.  

 

Use a circuit breaker or a disconnect switch to 
prevent accidental operation of the door during 
repair or maintenance works or after removing the 
safeties. 

 

All parts and components under tension and all 
electrical moving parts can cause serious injuries 
or even death. Installation, connection and start-up 
as well as repair and maintenance must be 
exclusively carried out by

 

trained door systems 

technicians

 

only. 

 

Remove all closing devices to avoid damages to 
the door or to the motorised apparatus. Block the 
(i) closing device (i) on the “open” position. If a 
closing has to remain active, use a release switch. 

The technical features of the gear reducer are stated on the motor ID plate and in this document.  
Please, conform to the following documents: these instructions, all other design documents necessary for 
motorisation, start-up procedures and wiring diagrams, National law provisions currently in force (concerning 
safety and prevention)  

 
 
 
 

Summary of Contents for LIFTER230C

Page 1: ...ORTONI SEZIONALI INDUSTRIALI GEAR REDUCER FOR INDUSTRIAL SECTIONAL DOORS MANUALE D USO E DI INSTALLAZIONE USE AND INSTALLATION MANUAL Daspi Automazione Cancelli S r l Via Copernico Malo Vicenza Italia...

Page 2: ...blocchi esistenti per evitare danni al portone Se per i blocchi devono restare attivi possibile installare un interruttore di sblocco Rimuovere prima dell installazione dell apriporta tutte le corde...

Page 3: ...a necessario che l albero di sollevamento sia adeguatamente dimensionato che il fissaggio non provochi tensioni sullo stesso e che si disponga di superfici adatte a fissare in maniera solida i support...

Page 4: ...ZATO DA Persona addestrata non accessibile al pubblico Gruppo 1 Zona pubblica Gruppo 2 Zona pubblica in genere Gruppo 3 Comando mediante azionamento continuato dell interruttore A B n d Attivazione a...

Page 5: ...nto torcente 80Nm 50 Nm Giri in uscita 24 giri min 24 giri min Durata inserzione S3 40 S3 20 Tensione d esercizio 400V 3 230V 1 Frequenza 50 Hz 50 Hz Corrente nominale 1 5 A 3 8 A Grado di protezione...

Page 6: ...could obstruct or damage the door In the case of active safety locks it is possible to install a release switch Remove all ropes and chains connected to the door before installing the opener DANGER h...

Page 7: ...t breakings serious injuries or even death For a safe installation the lifting shaft must be properly dimensioned fixations should not cause stress on the shaft and the available surface must provide...

Page 8: ...by the public Group 1 Public Zone Group 2 general Public zone Group 3 Continuous operation mode by switch activation A B Not available Continuous operation mode by sight pulse activation C C and D C a...

Page 9: ...er 0 30kW 0 30 kW Torque 80Nm 50 Nm Motor speed output power 24 rpm 24 rpm Insertion time S3 40 S3 20 Voltage 400V 3 230V 1 Frequency 50 Hz 50 Hz Nominal current 1 5 A 3 8 A Level of protection IP 44...

Page 10: ...Pagina 10 di 20 Revisione 00 08 Disegni dimensionali Dimensional drawings LIFTER230C LIFTER400C...

Page 11: ...Pagina 11 di 20 Revisione 00 08 I Disegni dimensionali Dimensional drawings LIFTER230R LIFTER400R...

Page 12: ...60335 1 EN 60335 2 103 BGR 232 Luogo Data Malo il 02 05 2007 Spinella Denis Funzione del firmatario Amministratore unico CE STATEMENT OF COMPLIANCE Manufacturer DASPI Automazione cancelli S r l via Co...

Page 13: ...uenti funzioni semaforo luce di cortesia chiusura automatica tempo di lavoro 2 Componenti principali S01 S02 pulsante d impostazione APERTURA S01 pulsante d impostazione CHIUSURA S02 X1 morsettiera al...

Page 14: ...a motore X4 Morsettiera selezione della tensione di rete Schema di collegamento finecorsa morsetto X5 e X2 Schema di collegamento di apparecchi di comando e di sicurezza Pulsante STOP Pulsante APERTUR...

Page 15: ...A rapporto d intermittenza 60 con durata della corsa di max 120 s Protezione 10A Consumo max 100 mA Tensione di comando 24V DC max 250mA assicurata dalla protezione autoripristinante per sensori ester...

Page 16: ...PENING S01 key to adjust the CLOSING S02 X1 Terminal to connect the main power supply 400Vac 230Vac X2 Terminal to connect motor emergency stop chain release and thermal protection X3 Terminal for com...

Page 17: ...afety limit switch N C contact S7 Switch to control the manual emergency device N C contact T1 Transformer X1 Terminal to connect the power supply X2 Terminal for the drive motor X4 Terminal to select...

Page 18: ...ght or traffic light How to do the connections with the logic card scheda logica terminal X3 With safety edges opto electric With resistive edges 8 2 KOhm Set micro Sw DIP 1 in OFF Set micro Sw DIP 1...

Page 19: ...through L1 L2 L3 PE 230 V o 400 V 50 60 Hz absorbed power max 2200 W 3 2 A Fuse protection 10A Absorbed power from push button control max 100 mA Tension 24V DC max 250mA Terminals 24V DC all termina...

Page 20: ...Pagina 20 di 20 Revisione 00 08 NOTE DASPI AUTOMAZIONE CANCELLI S r l Via Copernico 78 36034 Malo Vicenza Italia Tel 39 0445 602261 Fax 39 0445 585035 www daspi it info daspi it...

Reviews: