background image

Lux BT QSG 

(see also Thalia P or Libra CLX QRG)

Quick reference guides are not a replacement for the supplied instructions, they are supplementary 
Read and understand the installer warnings in the main instruction document first 
Always apply good, safe, state of the art engineering and electrical installation principles 
Safety of the completed installation is the ultimate responsibility of the installer 
This product is not suitable for DIY use and should only be installed and maintained by a trained, skilled, professional installer

Summary of Contents for LUX BT 2B

Page 1: ...the installer warnings in the main instruction document first Always apply good safe state of the art engineering and electrical installation principles Safety of the completed installation is the ultimate responsibility of the installer This product is not suitable for DIY use and should only be installed and maintained by a trained skilled professional installer ...

Page 2: ...Geometry This motor will work best when A B any other configuration will detract from its performance and could affect reliability A B C Lux BT A 135mm B 135mm C 1050mm Lux G BT A 195mm B 195mm C 1295mm ...

Page 3: ...Geometry Extreme difference between A and B should be avoided at all cost and will only work on the lightest gates in perfect locations and with perfect set up ...

Page 4: ...oke Limit The rams need a degree of travel left un used in the open and closed positions If these dimensions are exceeded the encoder will not accept the limit positions and give ER SU during the set up procedure ...

Page 5: ...G BT is used on gates over 3m length it must be used in non locking form Turn both valves fully anti clockwise after set up Ground stops are recommended in the open and closed positions Neither motor is recommended for use with wind affected gates Open and Close locks are provide on either side of the release valve ...

Page 6: ...10 11 14 15 41 42 43 Wiring Libra CLX Thalia P Use 3 core externally rated flex in accordance with BS7671 1 5mm2 up to 10m 2 5mm2 up to 20m ...

Page 7: ... Press and hold top button lift off at open point OK M2 Open Press and hold top button Lift off at open point OK M1 Open Press and hold middle button Lift off at close point OK M1 Close Press and hold middle button Lift off at close point OK M2 Close Run AUTOSET Increase N1T and N2T to 25 Increase SLOW SPEED to 35 Fit accessories one at a time and test each before moving on ...

Page 8: ...and hold top button lift off at open point OK M1 Open Press and hold top button Lift off at open point OK M2 Open Press and hold middle button Lift off at close point OK M2 Close Press and hold middle button Lift off at close point OK M1 Close Run AUTOSET Increase OPEN FORCE and CLOSE FORCE to 25 Increase SLOW SPEED to 35 Fit accessories one at a time and test each before moving on ...

Page 9: ...d to cut in at 700mm from closed Measure force time at 500mm distance in line with the motor Thalia P Increase close force slow speed to just below 150N Libra CLX Adjust N2T and SLOW speed to just below 150N Run a full set of tests Address all other risks as appropriate MD Compliance ...

Reviews: