Maintenance
Backwash Procedure:
1.
Insert
BW/Drain hose
push to connect and secure the other end away from
any equipment
2.
With the Versa Fresh Pak operating, turn the
Out valve
to
Backwash
and
wait till the gauges reach 60 psi
3.
Turn off Versa Fresh Pak by pressing down on the red
Switch
4.
Turn
In valve
to
Backwash
and let the system drain
5.
Once Drained, turn the
In valve
back to
Run
and
Out valve
to
Run
6.
Repeat step 2, 3, 4 and 5, at least 2 to 3 times to get a good membrane flush
7.
Backwash procedure complete, to return system back to normal operations
see Operations Instructions above
Membrane Integrity Tester (MIT) Procedure:
1.
With the Versa Fresh Pak operating, turn power off by pressing down
Switch,
wait till pressure gauges reach 0 psi.
2.
Turn
Out valve
to
Backwash
and
In valve
to
OFF