background image

PVE400M USER’S GUIDE 

 

2.2  Installing the camera 

 
 

PVE400M is bundled with 1/3" Sony Ex-View HAD CCD, Hi-
res weatherproof bullet camera. The camera comes with Fischer 
Automatic Latching, Self Aligned 5 pin connector.  Gently plug 
and rotate the connector until it mates and push to lock.  In this 
position the connector is securely locked and pulling the cable 
will not disconnect it.  Fix the camera using a head strap or 
helmet mount (optional).  The camera has a mark of a top 
position for easy orientation.  In order to unplug the camera, pull 
the bottom sleeve of the connector.  

or. 

 

 

2.3  Using other video/audio source 

 

PVE400M can accept any standard video source.  The optional 
PVE-AV split cable has a standard RCA female connector 
(Yellow) for video input.  PVE400M can provide 12V/200mA 
power for an external camera using a standard power jack. This 
power source is protected by resettable fuse with 400mA limit, to 
secure PVE400M from accidental shortage. 
The standard electret microphone can be connected to the audio 
jack.  PVE400M will provide 1.1V DC bias for the microphone 
on the same connect
See also the table in section 

8.3

 for the connector pin out, if the 

custom cable is needed. 

 

2.4  Powering up 

 

Press and hold the power button (Figure 2 -1) until the 

green LED

 is on (Figure 2 - 5).  The unit will be ready for 

operation as soon as the 

status LED

 is lighted (Figure 2 - 6).  To turn off, press and hold the power button again, 

until 

all

 

LEDs

 are off.  When the external power adapter is attached, the unit will turn on immediately. The 

power button works only for battery.  Alternatively the unit can be powered via AUX connector (see the table in 
section 

8.3

).  This is useful if the unit operates with an external power source, for example inside a car, or while 

stationary mounted.  
 

  

Warning

:  

 

Do not remove the battery, even if the unit is always working with the external power source.

Copyright © 2007 Darim Vision Co, All Rights Reserved

 

- 8 - 

Summary of Contents for PVE400M

Page 1: ...User s Guide Rev 1 2 November 21 2007 Copyright 2007 Darim Vision Co All Rights Reserved...

Page 2: ...m Vision Co All Rights Reserved No part of this reference manual may be reproduced or transmitted in any form or by any means without the prior written permission of this company Throughout this manua...

Page 3: ...FIGURATION 13 3 2 1 Wired connection configuration 13 3 2 2 Wireless connection configuration 14 3 3 VIDEO AND AUDIO CONFIGURATION 15 3 4 VIEWING VIDEO 17 3 5 MONITORING THE BATTERY STATUS 19 3 6 UPGR...

Page 4: ...st or from a Central Operations Control Centre delivering real time video and audio information from outdoor environments back to a centrally managed control location in order to communicate true Poin...

Page 5: ...se and connectors DC 12V output for camera power feed Up to 4 hours operating time on single Field replaceable battery Multi device Enterprise management from Darim s VideoSpider Console 1 2 Requireme...

Page 6: ...PVE400M USER S GUIDE 2 INSTALLATION STEPS This chapter describes the installation procedure of the PVE400M accessories Figure 2 PVE400M interface Copyright 2007 Darim Vision Co All Rights Reserved 6...

Page 7: ...the supplied antenna to RP SMA jack Figure 3 Attaching the supplied antenna Warning The only supplied antenna with 2 0dBi gain is certified to use with PVE400M when the device is used as wearable Cop...

Page 8: ...otected by resettable fuse with 400mA limit to secure PVE400M from accidental shortage The standard electret microphone can be connected to the audio jack PVE400M will provide 1 1V DC bias for the mic...

Page 9: ...ter plug to DC jack in the same way as using PVE P using custom cable if rigid connection required Aluminum case of PVE400M is electrically connected with internal ground signal negative The external...

Page 10: ...T568B on one side and Automatic Latching Self Aligned 10 pin connector on the other side Gently plug and rotate AUX side of the connector until it mates and push to lock In this position the connecto...

Page 11: ...192 168 1 250 static To access PVE400M for the first time using the wired connection PC must be on the same network subnet The network settings can be changed using the NETWORK tab see section 3 2 Ch...

Page 12: ...using the standard NTP protocol during boot time Most of Linux systems have NTP Daemon to synchronize time between machines The best option here is to put IP address of MeshManager system if it is bas...

Page 13: ...ent and DHCP range DHCP Client in this mode PVE400M will request IP address and all network configurations from the external DHCP server If IP address has been successfully obtained it will be shown i...

Page 14: ...he IP mode field allows you to select either DHCP Client Static IP Assignment or Disabled mode For Statically Provisioned mode use DHCP Client selection The MAC Address field is a read only parameter...

Page 15: ...tion for IP address Subnet Mask and Default Gateway if required If any changes have been made on this page click the Apply button otherwise simply select the other tab 3 3 Video and audio configuratio...

Page 16: ...eter field serves for specifying maximum allowed bit rate for video compression It depends on the link quality and the actual bit rate can vary but it will not exceed the set value of this field Make...

Page 17: ...on fields If any changes have been made on this page click the Apply button otherwise simply select other tab The Restart button will restart the streaming engine and video driver without complete reb...

Page 18: ...option is using Darim s Video Spider software it can be purchased separately The Video Spider software will you allow to monitor and record data from multiple PVE400M units The Video Spider software h...

Page 19: ...2V maximum The device will normally operate until the battery is discharged down to 3 0V and then shutdown The rechargeable Lithium Ion battery rated with capacity 6 8Ah if discharged till 2 5V It mea...

Page 20: ...off on cycle is recommended after the upgrade procedure If the status after the upgrade reports an error check the network connection to upgrade site if it can be accessed from the network segment of...

Page 21: ...ss is added to the list all other devices are automatically prevented from accessing with the exception of those devices from the list To add a new trusted address click the Add button Using the Delet...

Page 22: ...ault gateway for them Example Ext device 1 PVE400M Ethernet side PVE400M Wireless side IP 192 168 1 2 IP 192 168 1 250 IP 172 31 1 200 MASK 255 255 255 0 MASK 255 255 255 0 MASK 255 255 0 0 GW 192 168...

Page 23: ...ve rep Or send an e mail to usasales darim com The Regional Representative will be the first line of support for the product The latest version of the PVE400M User s Guide is available at www darimcct...

Page 24: ...s manual failure of the end user to follow the maintenance procedures in the service manual for the Product where a schedule is specified for regular replacement or maintenance or cleaning of certain...

Page 25: ...sures Reorient or relocate the receiving antenna Increase the separation between the PV400M and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is...

Page 26: ...symbol indicates that PVE400M is not certified to operate in France Outdoor use in France is restricted to 10mW EIRP for band 2454 2483 5 MHz Note CE mark is not applicable if WMC7300 is assembled in...

Page 27: ...ation time 3 5 hours depends of network condition External power 10 16V DC 2A Dimensions 134x113x37mm Weight 0 75kG without caring case Operating temperature 20 40C Humidity 0 95 Rating IP66 8 2 PVE C...

Page 28: ...Ethernet Rx Data 7 Ethernet Tx Data 8 RS232 ground 9 RS232 Rx 10 RS232 Tx Mating male connector Fischer S1031 A010 140 A V connector Pin Designation 1 Video in 2 Audio input 3 Audio ground 4 12V out...

Page 29: ...6 white green 3 Ethernet 7 orange 2 Ethernet 8 white blue 5 RS232 common 9 brown 8 RS232 Rx 10 blue 4 RS232 Tx Note Ethernet wired as straight through T568B DC power jack Center pin 10 16V 2A Max Stan...

Page 30: ...PVE RPC US US type Power cord for PVE PS PVE RPC EUR European type Power cord for PVE PS PVE RPC UK UK type Power cord for PVE PS PVE RPC AUS Australian type Power cord for PVE PS PVE VPS Vehicle DC...

Reviews: