IMPORTANT SAFETY INSTRUCTIONS 

Safety Instructions 

PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING ANY PRODUCTS OR 
DEVICES & KEEP FOR FUTURE REFERENCE. 

This manual contains important instructions for the installation and maintenance 
of G320 micro inverters. Before installing, please read these safety instructions 
carefully. Take special care to follow the warnings indicated on the unit itself as 
well as the safety instructions listed below. 
 

Safety Symbols 

To reduce the risk of injury and to ensure the continued safe operation of this 
product, the following safety instructions and warnings are marked in this 
manual. 
 

WARNING 

This indicates the risk of electric 
shock. The presence of high 
voltage levels may constitute a 

risk of injury or death to users and/or installers. 

CAUTION 

This indicates important 
information where failure to 
comply may result in safety 

hazards or cause damage to this product.

 

 

Safety Instructions 

 

Read  all  instructions  and  cautionary  marks  in  the  manual  carefully  before 
starting the installation. 

 

Do  not  attempt  to  repair  this  product;  it  does  not  contain  user-serviceable 
parts.  Repairs  and  internal  servicing  should  only  be  performed  by  authorized 
service personnel. 

 

Do not tamper with or open this product. Opening this product may result in 
electric shock. 

 

Perform  all  electrical  installations  in  accordance  with  all  applicable  local 
electrical codes and the National Electrical Code (NEC), ANSI/NFPA 70. 

 

Only  qualified  electrical  personnel  should  perform  the  electrical  installation 
and wiring of this product. 

 

Be aware that even without an external  voltage  source  connected, the  micro 
inverter may contain high voltages and there is a risk of electrical shock. 

 

Connect  the  micro  inverter  to  the  utility  grid  only  after  receiving  prior 
approval from the electrical utility company. 

 

The temperature of the heat sinks outside of the device can reach over 85

°

C in 

normal  operation.  To  reduce  risk  of  burns,  use  caution  when  working  with 

micro inverters. 

 

Do not disconnect the DC power source from the micro inverter without first 
disconnecting  the  AC  power  source.  Both  AC  and  DC  power  sources  must  be 
disconnected  before  servicing.  Be  aware  that  DC  power/voltage  is  generated 
when the photovoltaic array is exposed to light. 

 

Switch off the circuit breakers before installation and wirings. 

 

For  the  safety  of  installation,  remove  all  conductive  jewelry  or  equipment 
during the installation or service of the device parts, connector and/or wiring. 

 

Do  not  stand  on  a  wet  location  while  doing  installation  and  wirings.  Enclose 
the outer covering well before switch on the circuit breakers. 

 

The micro inverters should be installed as instructed in this manual. Failure to 
comply  with  these  precautions  or  with  specific  warnings  elsewhere  in  this 
manual violates safety standards of design, manufacture, and intended use of 
the device. The manufacturer assumes no liability for the customer’s failure to 
comply with these requirements. 

 

When  a  GFDI  fault  (Ground  fault)  occurs,  the  LED  will  flash  alternating 
between  orange  and  red.  Please  refer  to  the  POST-INSTALLATION  section  for 
more introductions. 

Surge Suppression 

Lightning  does  not  actually  need  to  strike  the  equipment  or  building  where  the 
PV system is installed to cause damage. Often, a strike nearby will induce voltage 
spikes in the electrical grid that can damage equipment.  Artificial spikes such as 
those  induced  by  electric  motors  starting  up  can  also  cause  damages  to  the 
equipment. 
 
The micro inverters have integral surge protection built-in; however, if the surge 
has sufficient energy, the built-in protection in the device would be exceeded and 
the  device  could  potentially  be  damaged.  Therefore,  external  surge  protection 
MUST be installed as part of any solar installation.   
 

WARNING

 

 

When installing a surge protection device (SPD), one MUST follow the original 
manufacturer’s  instructions  on  how  to  install  the  SPD  properly.  Incorrect 
installation  of  the  SPD  may  still  cause  damages  to  the  micro  inverters.  If  the 
installation  site  is  known  for  unstable  or  heavy  surges,  then  it  is  the 
responsibility  of  the  installer  to  make  sure  the  SPD  chosen  can  adequately 
protect the micro inverters. 

 
The following SPD specification is the minimum protection level that is required 

Summary of Contents for G320

Page 1: ...G320 MI CRO I NVERTER U S E R M A N U A L...

Page 2: ...4 PRE INSTALLATION 5 THE MICRO INVERTER 5 PV SYSTEM LAYOUT 5 PARTS AND TOOLS 5 COMPATIBILITY AND CAPACITY 6 AC TRUNK CABLE 6 GROUNDING OPTIONS 6 MICRO INVERTER LAYOUT 7 SURGE PROTECTION 7 INSTALLING T...

Page 3: ...urns use caution when working with micro inverters Do not disconnect the DC power source from the micro inverter without first disconnecting the AC power source Both AC and DC power sources must be di...

Page 4: ...G are bound together or DS73RS 120 where N and G are not bound together JDA D1 80 xxx VG R series http www jdauspice com uploads 2011 01 10 SPD_catalogue pdf FCC Compliance This equipment has been tes...

Page 5: ...to tap power from the center of the circuit so 2 segments of 9 and 10 modules total 19 for each circuit This maximizes the communication signal strength to the PLC box The use of a RS485 specific cabl...

Page 6: ...or four pins four wires Currently the four pin AC trunk cable is used Pin Wire Color Wire Usage 1 Black L1 2 Red L2 3 Green Ground 4 White Neutral Grounding Options Option 1 Integrated Grounding Inte...

Page 7: ...eeled off the micro inverter and adhered to the installation map template where the actual position on the roof would correspond to the same panel on the layout drawing Note Tracking micro inverter lo...

Page 8: ...icro inverter will be installed Then secure the cable on either side of the rack using cable clips or tie wraps Note the maximum pitch distance is 1050mm when modules are in portrait mode and 1700mm w...

Page 9: ...fully inserted WARNING Correct AC grounding and short circuit protection must be provided to ensure operational safety 6 2 Repeat for all 1T AC trunk cable in the AC branch circuit 6 3 After connect...

Page 10: ...ION WARNING Service changes to your electrical system should be carried out only by qualified electricians Do not attempt to repair this product it does not contain user serviceable parts Repairs and...

Page 11: ...od of time If the removed micro inverter will not be replaced with another micro inverter immediately connect a sealing cap to the T branch connector TROUBLESHOOTING Troubleshooting the Micro Inverter...

Page 12: ...contact the Technical Support at support darfon com TECHNICAL SPECIFICATIONS Micro Inverter G320 INPUT FROM PV DC Number of Panels per Inverter One Nominal Power STC of Each Panel 320 W Recommended ST...

Page 13: ...and keep track of the micro inverters placement by serial number Peel off and use secondary serial number label on the micro inverter Installer Array Name Site Address Azimuth Date ______________ She...

Page 14: ...1 4 NOTES Manufactured by Darfon Electronics Corp 167 Shan ying Road Gueishan Taoyuan 333 Taiwan R O C Tel 886 3 2508800 USA Office Darfon America Corp 103A Pioneer Way Mountain View CA 94041 Tel 1 65...