Copyright © 2008 – 2019 DARE!! Products
Page 24
General Commands (All Modes) Power Sensor, part 2
Command
Reply
Description
“STORE”
“OK”
Stores the current settings in
flash memory.
“AUTO_STORE <s>”
“OK”
Sets the auto store mode, with:
<s> = 0 (settings will not be
automatically stored)
<s> = 1 (settings will be stored in
flash after each change of the
settings)
“AUTO_STORE?”
“0” or “1”
Returns the current store setting.
”FREQUENCY <f>”
5
“OK”
Set the frequency <f> in kHz.
“FREQUENCY?”
“1300000 kHz”
Returns the frequency in kHz.
In this example: 1.300.000 kHz
“FREQUENCY? MIN”
“9 kHz”
Lowest measurable frequency.
In this example: 9kHz
“FREQUENCY? MAX”
“6000000 kHz”
Highest measurable frequency.
In this example: 6GHz
“FILTER AUTO”
“OK”
Sets the filter to automatic.
See specification for setting.
“FILTER <n>”
“OK”
Sets the number of samples used
to calculate the RMS power value,
with:
<n> = 1 = 10 samples
<n> = 2 = 30 samples
<n> = 3 = 100 samples
<n> = 4 = 300 samples
<n> = 5 = 1000 samples
<n> = 6 = 3000 samples
<n> = 7 = 5000 samples
“FILTER?”
“1” to “7” or “AUTO”
Returns the filter setting.
*
This table continues on the next page.
5
The frequency can be set with a resolution of 0,1 kHz from firmware version 2.4.x or higher