Chapter 1
Introduction
SCXI-1102/B/C User Manual
1-6
©
National Instruments Corporation
Custom Cables
The following table summarizes the custom cable information.
Unpacking
Your SCXI-1102/B/C module is shipped in an antistatic package to
prevent electrostatic damage to the module. Electrostatic discharge can
damage several components on the module. To avoid such damage in
handling the module, take the following precautions:
•
Ground yourself via a grounding strap or by holding a grounded
object.
•
Touch the antistatic package to a metal part of your SCXI chassis
before removing the module from the package.
•
Remove the module from the package and inspect the module for
loose components or any other sign of damage. Notify National
Instruments if the module appears damaged in any way. Do not
install a damaged module into your SCXI chassis.
•
Never touch the exposed pins of connectors.
Signal
Connector
SCXI–1102/B/C
Connector
Mating
Connector
Cable
Rear
AMP Inc. (1-103310-0)
50-pin male ribbon
cable header
Electronic Products
Division/3M (3425-7650)
or T&B/Ansley Corp.
(609-5041CE) 50-position
polarized ribbon-socket
connector
Electronic Products
Division/3M (3365/50)
or T&B/Ansley Corp.
(171-50) 50-conductor,
28 AWG stranded
ribbon cable
Front
Harting Electronik Inc.
(09-03-396-6921)
96-pin DIN C male
connector
AMP Inc. (535020;
right-angle pins) or Panduit
Corp. (100-096-434
straight-solder pins) 96-pin,
polarized, DIN C female
connector
N/A