background image

6

Installation

Remove all packing materials from the Xtreme. Check that all foam and plastic padding is removed.
Screw the equipment into a 19" rack. Connect all cables.

Always disconnect from electric mains power supply before cleaning or servicing.
Damages caused by non-observance are not subject to warranty.

Set Up and Operation

Before plugging the unit in, always make sure that the power supply matches the product specification
voltage. Do not attempt to operate a 120V specification product on 240V power, or vice versa.

Install this device on a flat surface, not bending or curved.

Do not supply power before 

all components of the system are

 set up and connected properly.

There are 3 different modes: Offline Mode, Online Mode, PC Software Operation

OFF LINE MODE

Switch on the power, the system accesses the OFFLINE mode.

A. Adjust the volume: turn CHA/CHB button to adjust the input level of CHA/CHB.
B. Setup the amplifier ID:
     Press CHA button for about 3 seconds, the LCD shows:

      SETUP   AMPLIFIER   ID
      DEVICE   NO.#1

     Then, turn CH A to change the amplifier ID from 1 to 255. Press CH A button again and save the setting.
C. Load program
     Press the CH B button for about 3 seconds, the LCD shows:

   LOAD  PROGRAM  P :    11

NO PEQ+XOVER+DELAY

     Then, turn CH A to select one program [ 1 -11 ]. Press

 

CH B button again, save the setting and load the

     selected program. At the same time, the LCD shows: LOADING…….. Several seconds later, LOADING is
     finished and the system returns to the menu
D. SETUP VOLUME PROTECT: Under menu LOAD PROGRAM, press the CH B button again for about 3
     seconds and then the LCD shows:

   VOLUME MUTE PROTECT
   AUTO MUTE : ON

    Turn the CH B button to switch on/off AUTO MUTE. Then, press the CHB button again to save the setting.
    AUTO MUTE: ON. When the power is on, the volume of CH A/CH B is automatically MUTE.
    AUTO MUTE: OFF. When the power is on, the volume of CH A/CH B returns to the setting, when the
                            power was off the last time.

Note

:

1. Program No. 11 is not used in the online mode without PEQ, XOVER and DELAY. The other 10 programs
    can be saved and recalled in the online mode.
2. The volume is automatically muted after every LOAD PROGRAM.
3. When the system switches from the online mode to the offline, the system can load the program that is
    saved in the online mode. At the same time, the volume is muted automatically.

Amplifier ID

Program Number
Program Name

Summary of Contents for Xtreme X-1300

Page 1: ...Xtreme X 1300 ORDERCODE D4172...

Page 2: ...need You can rely on DAP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work...

Page 3: ...Guide Warning Safety instructions Operating Determinations Description Features Overview Front side Overview Back side Installation Set Up and Operation OFF LINE Mode ON LINE Mode PC SOFTWARE Operati...

Page 4: ...rd and all connections with the mains with particular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Do not insert objects into air ven...

Page 5: ...volume to 0dB position Sometimes when you want to send one signal to more than one amplifier you should use a signal distributor If your Dap Audio device fails to work properly discontinue use immedi...

Page 6: ...designed signal generator sin wave and white noise S PDIF input output option Matrix control up to 255 units controlled by selecting address code Save and recall all parameters via PC parallel port 5...

Page 7: ...he impedance load of the loudspeaker or loudspeaker system must match the amplifier see technical specification Only use a speaker cable normally provided with one red and one black wire Do not use th...

Page 8: ...ess CH A button again and save the setting C Load program Press the CH B button for about 3 seconds the LCD shows LOAD PROGRAM P 11 NO PEQ XOVER DELAY Then turn CH A to select one program 1 11 Press C...

Page 9: ...device number 1 255 If this number is the same as the amplifier ID the LCD shows CONNECT SUCCESSFUL PC CONTROL DEVICE At that time the system can be tested by the DSP software All the functions from...

Page 10: ...ndent Bridge Bridge mode the output phase of the left and right channel is reversed Mono Mono mode the output phase of the left and right channel is the same Test menu Sine wave Sine wave Test generat...

Page 11: ...range 19 7Hz 20 2kHz Q value 0 4 128 3 Xover Click the Xover Button and then the parameters of the filter slope and frequency of HPF LPF can be set The minimum Frequency of LPF is not lower than the m...

Page 12: ...always to your advantage Periodically check that your cables are in good condition that they are correctly wired and that all their contacts are perfectly efficient a great number of problems faulty...

Page 13: ...the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 3 Remove the broken fuse If brown or unclear it is burned out 4 Insert the replacement fuse into th...

Page 14: ...ty 8 0 775V for rated power 0 775V for rated power 0 775V for rated power 0 775V for rated power 0 775V for rated power Input Impedance 20K balanced 10K unbalanced 20K balanced 10K unbalanced 20K bala...

Page 15: ...2004 DapAudio...

Reviews: