![Danyon DA-HP-16-230 Installation And Owner'S Manual Download Page 27](http://html2.mh-extra.com/html/danyon/da-hp-16-230/da-hp-16-230_installation-and-owners-manual_5124697027.webp)
: Copper wire
Proper power wiring connections
Use the same power supply, circuit breaker and leakage protectve device for the unit of cascade system
When connecting to the power supply terminal, use the circular wiring terminal with the insulation casing (see Figure 9.1).
If circular wiring terminal with the insulation casing cannot be used, please make sure that:
•
Do not connect two power cords with different diameters to the same power supply terminal (may cause overheating
of wires due to loose wiring) (See Figure 9.2).
Use power cord that conforms to the specifications and connect the power cord firmly. To prevent the cord from being
pulled out by external force, make sure it is fixed securely.
+
Power cord
Insulation tube
Circular wiring
terminal
Power Supply
Circuit Breaker
Manual switch
Wire Distribution Box
......
25
• The cascade function of the system only supports 8 machines at
most.
• In order to ensure the success of automatic addressing, all mach
ines must be connected to the same power supply and powered on
uniformly.
• Only the Master unit can connect the controller, and you must put
the SW3 to “on” of the master unit, the slave unit cannot connect the
controller .
• Please use the shielded wire, and the shield layer must be groun
ded.
• Engineering load wiring must meet the requirements of double in
sula
tion and the outermost insulation thickness ≥1mm .
• The engineering load wiring needs to be routed through pipelines or
walls .
CAUTION
Summary of Contents for DA-HP-16-230
Page 47: ......